Model: LS520 | Color: Silver
I. Product Parameters
| Project | Specification |
|---|---|
| Communication Method | RS485/Wireless/Wired |
| Voltage/Torque | 12V, 220V/1.2Nm |
| Speed | 112 RPM |
| Material | Aluminum Alloy |
| Adaptation to Track Types | Single/Double Track/Irregular Customization |
II. Core Functions and Advantages
- Silent Power
- Imported Motor Assembled in China, Running Volume Extremely Low (Almost Silent When Not Hanging on Track)
- Support for Watching Actual Demonstrations Video Verification
- Durable Design
- All Aluminum Alloy Shell, Wear Resistant and Corrosion Resistant
- Elliptical Narrow Edge Shape, Saving Installation Space
- Intelligent Control
- RS485 Protocol Supports Curtains to Stop at Any Position and Percentage Opening and Closing
- The remote control has a built-in timing function and a dry node interface for easy system integration
- Emergency operation
- Power outage manual mode (with clutch)
- Hand pulled soft start function (can be turned off separately)
- Flexible adaptation
- Automatic travel adjustment, supporting track folding transportation
- Irregular orbit can be customized (90 °/135 °, etc.)
3, Preparation before installation
📏 Measurement Guide
- Single track Curtain BoxReserved width ≥ 15cm
- Double track curtain boxReserved width ≥ 25cm
- Track length=Wall spacing -4cm
📝 Purchase requires information to be provided
Curtain type:□ Double opening curtain (center to both sides) □ Single opening curtain (single-sided opening)
Curtain length:____ cm (example: 352cm)
Curtain height:□ 3M □ 6M
Motor position:□ Left side □ Right side
Is it irregular:□ Yes (drawings required) □ No
IV. Purchase and after-sales process
- Submission of dimensions→ 2Factory processing (2-3 days)→ 3Shipping of track accessories (freight collect)→ 4Motor and controller shipment
⚠️ Important Notice
- Returns are not supported: Customized tracks cannot be reused, only motors can be recycled
- Size modification:
- Only supports shortening once (cannot be lengthened)
- Exchange due to measurement errors requires self payment of round-trip shipping costs
V. Technical support
If you need irregular track design, tension calculation, or system integration solutions, please contact the technical team to provide drawings and scene descriptions.
Service Hotline: 18801054468
VI. Communication Protocol
1. Communication Basic Parameters
| Parameters | Value |
|---|---|
| Baud Rate | 9600 bps |
| Data bits | 8-bit |
| Stop bit | 1-bit |
| Parity check | No check |
| Check method | CRC-16/MODBUS |
| Polynomial | 0x8005 |
| Initial value | 0xFF |
2. Data frame structure
[起始符 0x55][设备地址(2字节)][功能码][数据地址][数据内容][CRC16]
Field description:
- Device address:
- IDUH(high byte): Superior device address, cannot be
0x00Or0xFF - IDUL(low byte): Local address, cannot be
0x00Or0xFF - Broadcast address:
0x0000(full control instruction, device does not return data) - Default address:
0xFEFE(effective after factory reset)
- Function code:
0x01: Read command (query status)0x02Write commands (configure parameters)0x03Control commands (on/off/stop, etc.)0x04: Request command (slave requests allocation of address)
- data addressDetermine the specific type of operation (see table below).
3. Core Instruction Lookup Table
Example defaults to0x12 0x34, but needs to be replaced with the target address
1. Control Command (Function Code0x03)
| Operation | Data Address) | Data Content | Example (Hexadecimal) |
|---|---|---|---|
| Open | 0x01 | None | 55 12 34 03 01 AD 8A |
| Close | 0x02 | None | 55 12 34 03 02 ED 8B |
| Stop | 0x03 | None | 55 12 34 03 03 2C 4B |
| Percentage | 0x04 | 0x00~0x64 | 55 12 34 03 04 1E C8 E5(30%) |
| Delete Journey | 0x07 | None | 55 12 34 03 07 2D 88 |
| Factory Recovery | 0x08 | None | 55 12 34 03 08 6D 8C |
2. Read Command (Function Code0x01)
| Query Content | Data Address | Return Data Description |
|---|---|---|
| Current Position | 0x02 | 0x00~0x64(Percentage,0xFFis uncalibrated) |
| Motor Direction | 0x03 | 0x00Default Direction,0x01Reverse |
| Manual Pull Enable Status | 0x04 | 0x00On,0x01Off |
| Motor Status | 0x05 | 0x00Stop,0x01Open,0x02Close |
3. Write Command (Function Code0x02)
| Configuration Item | Data Address | Data Content | Example (Hexadecimal) |
|---|---|---|---|
| Set Address | 0x00 | New Address (2 bytes) | 55 00 00 02 00 12 34 50 7F(Set as0x1234) |
| Reverse Direction | 0x03 | 0x01Reverse) | 55 12 34 02 03 01 9D 5B |
| Close Hand Pull | 0x04 | 0x01Disable | 55 12 34 02 04 01 2C 9A |
4. Scenario Mode (A2/A3 Version Function)
| Operation | Data Address | Data Content | Example (Hexadecimal) |
|---|---|---|---|
| Set Scenario | 0x09 | 0x01~0x14 | 55 12 34 03 09 01 8D BD(Scenario 1) |
| Run Scenario | 0x0A | 0x01~0x14 | 55 12 34 03 0A 01 8D 4D(Run Scenario 1) |
| Delete Scenario | 0x0B | 0x01~0x14 | 55 12 34 03 0B 01 8C DD(Delete Scenario 1) |
4. Address Setting Process
- Slave Request Address:
- Press and hold the motor setting button for 5 seconds, the LED flashes twice, and then release.
- Slave sent:
55 FE 04 01 BB 14.
- Host assigned address:
- Host replied:
55 00 00 02 00 12 34 50 7F(assigned address is0x1234).
5. Precautions
- Calibration Requirements:
- Before using percentage control, it is necessary to perform a full open/full close operation to calibrate the stroke.
- is not calibrated (returns
0xFF), the percentage instruction is invalid.
- Broadcast instruction:
- Address set to
0x0000can control all devices in the group, but the devices do not return data.
- Error Handling:
- CRC Check Failed: Check the baud rate and terminal resistance (120 Ω should be connected at both ends).
- Motor overload: Reduce track resistance or check load.
6. Quick Reference Formula
55开头是起始,地址两字跟后边,
功能码定读/写/控,数据地址填中间。
校验CRC别忘算,群控地址0000填。
百分比需先校准,情景模式按号编! Product Purchase:https://item.taobao.com/item.htm?ft=t&id=673185599289