Langsen Motor Product Manual

freeFree Technical Resource

This content is free to read, suitable for basic learning and search traffic.

Langsen Motor Product Manual
Langsen Motor Product ManualFigure

Model: LS520 | Color: Silver

I. Product Parameters

ProjectSpecification
Communication MethodRS485/Wireless/Wired
Voltage/Torque12V, 220V/1.2Nm
Speed112 RPM
MaterialAluminum Alloy
Adaptation to Track TypesSingle/Double Track/Irregular Customization

II. Core Functions and Advantages

  1. Silent Power
  • Imported Motor Assembled in China, Running Volume Extremely Low (Almost Silent When Not Hanging on Track)
  • Support for Watching Actual Demonstrations Video Verification
  1. Durable Design
  • All Aluminum Alloy Shell, Wear Resistant and Corrosion Resistant
  • Elliptical Narrow Edge Shape, Saving Installation Space
  1. Intelligent Control
  • RS485 Protocol Supports Curtains to Stop at Any Position and Percentage Opening and Closing
  • The remote control has a built-in timing function and a dry node interface for easy system integration
  1. Emergency operation
  • Power outage manual mode (with clutch)
  • Hand pulled soft start function (can be turned off separately)
  1. Flexible adaptation
  • Automatic travel adjustment, supporting track folding transportation
  • Irregular orbit can be customized (90 °/135 °, etc.)

3, Preparation before installation

📏 Measurement Guide

  • Single track Curtain BoxReserved width ≥ 15cm
  • Double track curtain boxReserved width ≥ 25cm
  • Track length=Wall spacing -4cm

📝 Purchase requires information to be provided

Curtain type:□ Double opening curtain (center to both sides) □ Single opening curtain (single-sided opening)
Curtain length:____ cm (example: 352cm)
Curtain height:□ 3M □ 6M
Motor position:□ Left side □ Right side
Is it irregular:□ Yes (drawings required) □ No

IV. Purchase and after-sales process

  1. Submission of dimensions→ 2Factory processing (2-3 days)→ 3Shipping of track accessories (freight collect)→ 4Motor and controller shipment

⚠️ Important Notice

  • Returns are not supported: Customized tracks cannot be reused, only motors can be recycled
  • Size modification:
  • Only supports shortening once (cannot be lengthened)
  • Exchange due to measurement errors requires self payment of round-trip shipping costs

V. Technical support

If you need irregular track design, tension calculation, or system integration solutions, please contact the technical team to provide drawings and scene descriptions.

Service Hotline: 18801054468

VI. Communication Protocol

1. Communication Basic Parameters

ParametersValue
Baud Rate9600 bps
Data bits8-bit
Stop bit1-bit
Parity checkNo check
Check methodCRC-16/MODBUS
Polynomial0x8005
Initial value0xFF

2. Data frame structure

[起始符 0x55][设备地址(2字节)][功能码][数据地址][数据内容][CRC16]  


Field description:

  1. Device address:
  • IDUH(high byte): Superior device address, cannot be0x00Or0xFF
  • IDUL(low byte): Local address, cannot be0x00Or0xFF
  • Broadcast address: 0x0000(full control instruction, device does not return data)
  • Default address: 0xFEFE(effective after factory reset)
  1. Function code:
  • 0x01: Read command (query status)
  • 0x02Write commands (configure parameters)
  • 0x03Control commands (on/off/stop, etc.)
  • 0x04: Request command (slave requests allocation of address)
  1. data addressDetermine the specific type of operation (see table below).

3. Core Instruction Lookup Table

Example defaults to0x12 0x34, but needs to be replaced with the target address

1. Control Command (Function Code0x03)

OperationData Address)Data ContentExample (Hexadecimal)
Open0x01None55 12 34 03 01 AD 8A
Close0x02None55 12 34 03 02 ED 8B
Stop0x03None55 12 34 03 03 2C 4B
Percentage0x040x00~0x6455 12 34 03 04 1E C8 E5(30%)
Delete Journey0x07None55 12 34 03 07 2D 88
Factory Recovery0x08None55 12 34 03 08 6D 8C

2. Read Command (Function Code0x01)

Query ContentData AddressReturn Data Description
Current Position0x020x00~0x64(Percentage,0xFFis uncalibrated)
Motor Direction0x030x00Default Direction,0x01Reverse
Manual Pull Enable Status0x040x00On,0x01Off
Motor Status0x050x00Stop,0x01Open,0x02Close

3. Write Command (Function Code0x02)

Configuration ItemData AddressData ContentExample (Hexadecimal)
Set Address0x00New Address (2 bytes)55 00 00 02 00 12 34 50 7F(Set as0x1234)
Reverse Direction0x030x01Reverse)55 12 34 02 03 01 9D 5B
Close Hand Pull0x040x01Disable55 12 34 02 04 01 2C 9A

4. Scenario Mode (A2/A3 Version Function)

OperationData AddressData ContentExample (Hexadecimal)
Set Scenario0x090x01~0x1455 12 34 03 09 01 8D BD(Scenario 1)
Run Scenario0x0A0x01~0x1455 12 34 03 0A 01 8D 4D(Run Scenario 1)
Delete Scenario0x0B0x01~0x1455 12 34 03 0B 01 8C DD(Delete Scenario 1)

4. Address Setting Process

  1. Slave Request Address:
  • Press and hold the motor setting button for 5 seconds, the LED flashes twice, and then release.
  • Slave sent:55 FE 04 01 BB 14.
  1. Host assigned address:
  • Host replied:55 00 00 02 00 12 34 50 7F(assigned address is0x1234).

5. Precautions

  1. Calibration Requirements:
  • Before using percentage control, it is necessary to perform a full open/full close operation to calibrate the stroke.
  • is not calibrated (returns0xFF), the percentage instruction is invalid.
  1. Broadcast instruction:
  • Address set to0x0000can control all devices in the group, but the devices do not return data.
  1. Error Handling:
  • CRC Check Failed: Check the baud rate and terminal resistance (120 Ω should be connected at both ends).
  • Motor overload: Reduce track resistance or check load.

6. Quick Reference Formula

55开头是起始,地址两字跟后边,  
功能码定读/写/控,数据地址填中间。  
校验CRC别忘算,群控地址0000填。  
百分比需先校准,情景模式按号编!  

Product Purchase:https://item.taobao.com/item.htm?ft=t&id=673185599289

Related Tags
Put this resource to use in a real project?

Go to the Tool Center for message parsing, CRC verification and device debugging, or submit your requirements for selection and integration advice.

Engineer Membership

Turn this article into actionable debugging resources

After activation, you can use advanced message parsing, resource pack downloads, code examples, engineering cases and priority technical support, suitable for real project delivery.

Unlimited Advanced Tools
Resource & Code Packs
Complete Engineering Case Library
Priority Technical Support

Leave a Reply

Your email address will not be published. Required fields are marked *.