Relay switch control-05 00 00 restore disconnect relay-00 00
| Address | Power code | Register address | data Verification | Starting address |
| 01 | 05 | 00 00 | 00 00 | CRC16HCRC16L |
| Perform conduction 00 00Disconnect action Action conducting relay | FF 00 Restore the disconnect relay 00 00 give an example | |||
The:
Road open 1 The (05) : 01050000FF008C3A
Road Pass 1 The (05) : 010500000000CDCA
Road open 2 The (05) : 01050001FF00DDFA
Road Pass 2 The (05) : 0105000100009C0A
Road open 3 The (05) : 01050002FF002DFA
Road Pass 3 The (05) : 0105000200006C0A
Road open 4 The (05) : 01050003FF007C3A
Road Pass 4 The (05) : 0105000300003DCA
Road open 5 The (05) : 01050004FF00CDFB
Road Pass 5 The (05) : 0105000400008C0B
Road open 6 The (05) : 01050005FF009C3B
Road Pass 6 The (05) : 010500050000DDCB
Road open 7 The (05) : 01050006FF006C3B
Road Pass 7 The (05) : 0105000600002DCB
Road open 8 The (05) : 01050007FF003DFB
Road Pass 8 The (05) : 0105000700007C0B
Road open 9 The (05) : 01050008FF000DF8
Road Pass 9 The (05) : 0105000800004C08
Road open 10 The (05) : 01050009FF005C38
Road Pass 10 The (05) : 0105000900001DC8
Road open 11 The (05) : 0105000AFF00AC38
Road Pass 11 The (05) : 0105000A0000EDC8
Road open 12 The (05) : 0105000BFF00FDF8
Road Pass 12 No. (05) : 0105000B0000BC08
No. 13 Road open (05) : 0105000CFF004C39
The 13 Road Pass (05) : 0105000C00000DC9
The 14 Road open (05) : 0105000DFF001DF9
The 14 Road Pass (05) : 0105000D00005C09
The 15 Road open (05) : 0105000EFF00EDF9
The 15 Road Pass (05) : 0105000E0000AC09
The 16 Road open (05) : 0105000FFF00BC39
The 16 Road Pass (05) : 0105000F0000FDC9
Relay pulse control-05 Function code- Fixed 2S
| Address | Function code | Register address | data Verification | Starting address |
| 01 | 05 | 30 00 | 00 00 | CRC16H CRC16L |
| Execute point pulse 30 00 Conduction 2S Automatic disconnection 2S Move | FF 00 Make a conducting relay Hui 00 00 Disconnecting the relay an electric appliance give an example |
The:
Road 1 Jog (The 2S) : 01053000FF00833A
Road 2 Jog (The 2S) : 01053001FF00D2FA
Road 3 Jog (The 2S) : 01053002FF0022FA
Road 4 Jog (The 2S) : 01053003FF00733A
Road 5 Jog (The 2S) : 01053004FF00C2FB
Road 6 Jog (The 2S) : 01053005FF00933B
Road 7 Jog (The 2S) : 01053006FF00633B
Road 8 Jog (The 2S) : 01053007FF0032FB
Road 9 jog (jog 2S) : 01053008FF0002F8
The 10 Road (Jog 2S) : 01053009FF005338
The 11 Road (Jog 2S) : 0105300AFF00A338
The 12 Road (Jog 2S) : 0105300BFF00F2F8
The 13 Road (Jog 2S) : 0105300CFF004339
The 14 Road (Jog 2S) : 0105300DFF0012F9
The 15 Road (Jog 2S) : 0105300EFF00E2F9
The 16 Road (Jog 2S) : 0105300FFF00B339
The 17 Road (Jog 2S) : 01053010FF0082FF
The 18 Road (Jog 2S) : 01053011FF00D33F
The 19 Road (Jog 2S) : 01053012FF00233F
The 20 Road (Jog 2S) : 01053013FF0072FF
The 21 Road (Jog 2S) : 01053014FF00C33E
The 22 Road (Jog 2S) : 01053015FF0092FE
The 23 Road (Jog 2S) : 01053016FF0062FE
The 24 Road (Jog 2S) : 01053017FF00333E
Relay reversal control-05 Function code
| Address | Function code | Register address | data Verification | Starting address |
| 01 | 05 | 50 00 | 00 00 | CRC16H CRC16L |
| Perform a reversal action 50 00 Move | FF 00 Perform conduction relay an electric appliance Hui00 00 Disconnecting the relay electrical appliance electrical appliance |
give an example:
The 1 Road reversal: 01055000FF009D3A
The 2 Road reversal: 01055001FF00CCFA
The 3 Road reversal: 01055002FF003CFA
The 4 Road reversal: 01055003FF006D3A
The 5 Road reversal: 01055004FF00DCFB
The 6 Road reversal: 01055005FF008D3B
The 7 Road reversal: 01055006FF007D3B
The 8 Road reversal: 01055007FF002CFB
The 9 Road reversal: 01055008FF001CF8
The 10 Road reversal: 01055009FF004D38
The 11 Road reversal: 0105500AFF00BD38
The 12 Road reversal: 0105500BFF00ECF8
The 13 Road reversal: 0105500CFF005D39
The 14 Road reversal: 0105500DFF000CF9
The 15 Road reversal: 0105500EFF00FCF9
The 16 Road reversal: 0105500FFF00AD39
The 17 Road reversal: 01055010FF009CFF
The 18 Road reversal: 01055011FF00CD3F
The 19 Road reversal: 01055012FF003D3F
The 20 Road reversal: 01055013FF006CFF
The 21 Road reversal: 01055014FF00DD3E
The 22 Road reversal: 01055015FF008CFE
The 23 Road reversal: 01055016FF007CFE
The 24 Road reversal: 01055017FF002D3E
The 25 Road reversal: 01055018FF001D3D
Relay fully open and fully closed control-05 Function code
| Address | Power code | Register address | data Verification | Register |
| 01 | 05 | 00 00 | 00 00 | CRC16H CRC16L |
| Fully conductive 00 32Fully conductive 00 33Completely disconnected 00 34 Reverse disconnection | FF 00 Action conducting relay 00 00 Restore the disconnect relay |
Relay switch control-06 Function code
| Address | Merit Code | Register address | data Verification | Starting address |
| 01 | 06 | 10 00 | 00 00 | CRC16HCRC16L |
| Perform conduction 10 00Disconnect action Move | 00 01 Perform conduction relay an electric appliance Hui00 00 Disconnecting the relay an electric appliance give an example |
The:
Road open 1 The (06) : 0106100000014CCA
Road Pass 1 The (06) : 0106100000008D0A
Road open 2 The (06) : 0106100100011D0A
Road Pass 2 The (06) : 010610010000DCCA
Road open 3 The (06) : 010610020001ED0A
Road Pass 3 The (06) : 0106100200002CCA
Road open 4 The (06) : 010610030001BCCA
Road Pass 4 The (06) : 0106100300007D0A
Road open 5 The (06) : 0106100400010D0B
Road Pass 5 The (06) : 010610040000CCCB
Road open 6 The (06) : 0106100500015CCB
Road Pass 6 The (06) : 0106100500009D0B
Road open 7 The (06) : 010610060001ACCB
Road Pass 7 The (06) : 0106100600006D0B
Road open 8 The (06) : 010610070001FD0B
Road Pass 8 The (06) : 0106100700003CCB
Road open 9 The (06) : 010610080001CD08
Road Pass 9 The (06) : 0106100800000CC8
Road open 10 Road open (06) : 0106100900019CC8
The 10 Road Pass (06) : 0106100900005D08
The 11 Road open (06) : 0106100A00016CC8
The 11 Road Pass (06) : 0106100A0000AD08
The 12 Road open (06) : 0106100B00013D08
The 12 Road Pass (06) : 0106100B0000FCC8
The 13 Road open (06) : 0106100C00018CC9
The 13 Road Pass (06) : 0106100C00004D09
The 14 Road open (06) : 0106100D0001DD09
The 14 Road Pass (06) : 0106100D00001CC9
The 15 Road open (06) : 0106100E00012D09
The 15 Road Pass (06) : 0106100E0000ECC9
The 16 Road open (06) : 0106100F00017CC9
The 16 Road Pass (06) : 0106100F0000BD09
Relay pulse output-06 Function code-Adjustable time
| Address | Function code | Register address | data Verification | Starting address |
| 01 | 06 | 00 00 | 00 00 | CRC16H CRC16L |
| Execute point pulse 00 00 Automatic disconnection Time unit | give an example ms |
Pulse:
The 2SRoad 1 Custom jog (The) : 0106000003E88974
Road 2 Custom jog (The) : 0106000103E8D8B4
Road 3 Custom jog (The) : 0106000203E828B4
Road 4 Custom jog (The) : 0106000303E87974
Road 5 Custom jog (The) : 0106000403E8C8B5
Road 6 Custom jog (The) : 0106000503E89975
road 7 road (Custom jog) : 0106000603E86975
The 8 Road (Custom jog) : 0106000703E838B5
The 9 Road (Custom jog) : 0106000803E808B6
The 10 Road (Custom jog) : 0106000903E85976
The 11 Road (Custom jog) : 0106000A03E8A976
The 12 Road (Custom jog) : 0106000B03E8F8B6
The 13 Road (Custom jog) : 0106000C03E84977
The 14 Road (Custom jog) : 0106000D03E818B7
The 15 Road (Custom jog) : 0106000E03E8E8B7
The 16 Road (Custom jog) : 0106000F03E8B977
The 17 Road (Custom jog) : 0106001003E888B1
The 18 Road (Custom jog) : 0106001103E8D971
The 19 Road (Custom jog) : 0106001203E82971
The 20 Road (Custom jog) : 0106001303E878B1
The 21 Road (Custom jog) : 0106001403E8C970
The 22 Road (Custom jog) : 0106001503E898B0
The 23 Road (Custom jog) : 0106001603E868B0
The 24 Road (Custom jog) : 0106001703E83970
The 25 Road (Custom jog) : 0106001803E80973
The 26 Road (Custom jog) : 0106001903E858B3
The 27 road (Custom jog) : 0106001A03E8A8B3
The 28 Road (Custom jog) : 0106001B03E8F973
The 29 Road (Custom jog) : 0106001C03E848B2
The 30 Road (Custom jog) : 0106001D03E81972
Multi channel relay control-0F Function code
| Address | Function code | Register starting address | Register length | Data length | data Verification | Can be set |
| 01 | 0F | 00 00 | 00 08 | 02 | FF 00 | CRC16H CRC16L |
| Starting address1-255 | Simultaneously switch 0000 Starting address Sequential conduction 0100 Interval 500ms Starting address Sequential disconnection 0200 Interval 500ms Starting address Sequential conduction 0300 Interval 1000ms Starting address Sequential conduction 0400 Interval 1000ms Starting address Sequential conduction 0500 Interval 2000ms Starting address Sequential communication 0600 Interval 2000ms Control continuity | A relay 8 The byte length of the following data | All relays are conducting | FF 8 Multi channel relay control |
Function code-10 Address
| Function code | Register starting address | Register length | Data length | data Verification | Can be | Set up |
| 01 | 10 | 00 00 | 00 08 | 10 | 00 00 00 01… . | CRC16H CRC16L |
| Place Starting address Simultaneously switch1-255 | Starting address 0000 jog starting address 0100 jog Time The interval is a unit of register valuems 0-65535ms Starting address 0500 Delayed lead The communication time is measured in units of register values ms 0-65535ms Starting address 0600 Delay interruption The disconnection time is measured in units of register values ms 0-65535ms | Control continuity 8 A relay | The byte length of the following data | 00 00 to break off00 01 Conduction |
Read relay status instructions-01 Function code
| send out | Address | Function code | Register address | Read the length | Verification | |
| 01 | 01 | 00 00 | 00 08 | CRC16H CRC16L | ||
| return | Address | Function code | Byte count | data Verification | From right to left represents opening | |
| 01 | 01 | 01 | 18 | CRC16H CRC16L | ||
| 18=00011000 Start reading the relay status give an example | ||||||
| send out | ||||||
| Address | Function code | Register address | Read the length | Verification | Read from the beginning of the first relay | |
| 01 | 01 | 00 00 | 00 10 | CRC16H CRC16L | Relay status 16return | |
| Address | Function code | Byte count | data Verification | Representative | Road | |
| 01 | 01 | 02 | 18 03 | CRC16H CRC16L | ||
| 18 Representative 1-8 Road 03 Read the status of the relay 9- 16 Function code | ||||||
Each status can be read separately-03 Address-Merit
| Code | Register starting address Read the number of channels | Verification | Starting address | Corresponding to the first route |
| 01 | 03 | 10 00 | 00 08 | CRC16H CRC16L |
| Example 10 00 Corresponding to the first route |
Example:
Read 1-8 Road 01031000000840CC
Read the switch status-02 Function code
| send out | Address | Function code | Register address | Read the length | Verification | |
| 01 | 02 | 00 00 | 00 08 | CRC16H CRC16L | ||
| return | Address | Function code | Byte count | data Verification | From right to left represents opening | |
| 01 | 02 | 01 | 18 | CRC16H CRC16L | ||
| 18=00011000 The initial reading of the switch status give an example | ||||||
| send out | ||||||
| Address | Function code | Register address | Read the length | Verification | Read from the beginning of the first relay | |
| 01 | 02 | 00 00 | 00 10 | CRC16H CRC16L | A switch status 16return | |
| Address | Function code | Byte count | data Verification | Representative | Road | |
| 01 | 02 | 02 | 18 03 | CRC16H CRC16L | ||
| 18 Representative 1-8 Road 03 Read the switch status 9- 16 Function code | ||||||
Can read the status of a single channel-03 Address-Merit
| Code | Register starting address Read the number of channels | Verification | Starting address | Corresponding to the first route |
| 01 | 03 | 30 00 | 00 08 | CRC16HCRC16L |
| Read analog data 30 00 Function code |
Address-03 Function code
| Register starting address | Read the number of registers | Verification | Address of analog storage register | Verification |
| 01 | 03 | 00 00 | 00 02 | CRC16L CRC16H |
| Low byte before high byte after | CRC Address function code | |||
| 1 address 1 2 function code 03 Read register data 3 Register starting address 4 The number of registers read 5 VerificationCRC16 StandardCRCVerification | ||||
Register location table
| PLC Configuration address | Register address | Parameters | Parameter description | Read and write |
| Relay control and status reading registers | 05 Control relay01 Read the status of the relay | |||
| 40001 | 0x0000 | The 1 Road relay | Readable and written | R/W |
| 40002 | 0x0001 | The 2 Road relay | Readable and written | R/W |
| …… | ||||
| 40010 | 0x0009 | The 10 Road relay | Readable and written | R/W |
| 40011 | 0x000A | The 11 Road relay | Readable and written | R/W |
| …… | ||||
| 40024 | 0x0018 | The 24 Road relay | Readable and written | R/W |
| Switch input status register | 02 Function code reference 3.4 Chapter | |||
| 40001 | 0x0000 | The 1 Road switch quantity | Read only | R |
| 40002 | 0x0001 | The 2 Road switch quantity | Read only | R |
| …… | ||||
| 40010 | 0x0009 | The 10 Road switch quantity | Read only | R |
| 40011 | 0x000A | The 11 Road switch quantity | Read only | R |
| …… | ||||
| 40025 | 0x0018 | The 24 Road switch quantity | Read only | R |
| Analog data acquisition | 03 Function code reference 3.5 Chapter | |||
| Analog position | Register address | Data type | ||
| The first route | 00 00 | Unsigned integer 100 Multiplier value | ||
| The second path | 00 01 | Unsigned integer 100 Doubling value | ||
| ….. | Unsigned integer 100 Multiplier value | |||
| The eighth route | 00 07 | Unsigned integer 100 Multiplier value | ||
| The ninth route | 00 08 | Unsigned integer 100 Multiplier value | ||
| Please refer to the actual device you received for the number of analog quantities | ||||