DGH 8-channel power sequencer RS232 serial communication protocol

freeFree Technical Resource

This content is free to read, suitable for basic learning and search traffic.

DGH 8-channel power sequencer RS232 serial communication protocol
DGH 8-channel power sequencer RS232 serial communication protocolFigure

Baud rate: 19200

Data bits : 8

Inspection position : None

Stop position : 1

Host remote control request code (EquipmentIPThe default address when leaving the factory is1)
Function Central control code instructions
CH1 Open55 01 A0 00 01 A0
CH2 Open55 01 A0 00 02 A3
CH3 Open55 01 A0 00 03 A2
CH4 Open55 01 A0 00 04 A5
CH5 Open55 01 A0 00 05 A4
CH6 Open55 01 A0 00 06 A7
CH7 Open55 01 A0 00 07 A6
CH8 Open55 01 A0 00 08 A9
CH1 close55 01 A1 00 01 A1
CH2 close55 01 A1 00 02 A2
CH3 close55 01 A1 00 03 A3
CH4 close55 01 A1 00 04 A4
CH5 close55 01 A1 00 05 A5
CH6 close55 01 A1 00 06 A6
CH7 close55 01 A1 00 07 A7
CH8 close55 01 A1 00 08 A8
Open sequentially55 01 A4 00 00 A5
Reverse order closure55 01 A5 00 00 A4
Simultaneously open55 01 A2 00 00 A3
Simultaneously close55 01 A3 00 00 A2

Related Tags
Put this resource to use in a real project?

Go to the Tool Center for message parsing, CRC verification and device debugging, or submit your requirements for selection and integration advice.

Engineer Membership

Turn this article into actionable debugging resources

After activation, you can use advanced message parsing, resource pack downloads, code examples, engineering cases and priority technical support, suitable for real project delivery.

Unlimited Advanced Tools
Resource & Code Packs
Complete Engineering Case Library
Priority Technical Support

Leave a Reply

Your email address will not be published. Required fields are marked *.