Modbus is one of the most common communication protocols in the industrial control field, and thus, it is also one of the commonly used protocols in PLCs. Many PLCs support the Modbus protocol and can communicate with other devices through the Modbus protocol. The Modbus protocol can be used in both serial communication and Ethernet communication, making it a very flexible and widely applied protocol. Therefore, it can be said that Modbus is not niche in PLCs. This article references https://blog.csdn.net/w181108233/article/details/124734830, introducing register configuration examples for 21 common PLC devices, accompanied by screenshots of MThings data configuration for Modbus Messenger.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图
1. Mitsubishi FX3G-40MR/ES-A: X components support Modbus function code 02; Y components support Modbus function codes 01, 05, and 15; D components support Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图1
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图2
2. Siemens S7-200 CPU226 I components support Modbus function code 02; Q components support Modbus function codes 01, 05, and 15; V components support Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图3
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图4
3. Omron CP1H-X40DR-A CIO0 components support Modbus function code 02; CIO100 component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图5
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图6
4. Panasonic AFPX-C40R X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; DT component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图7
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图8
5. Delta DVP-12SA2 X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图9
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图10
6. Xinjin XC5-48 X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图11
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图12
7. Yonghong FBs-40MC X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图13
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图14
8. Changle XBC-DR40S P0 component supports Modbus function code 02; P40 component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图15
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图16
9. Inovance H2u-2416MT-XP X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图17
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图18
10. INVT IVC2H-1616MAT6 X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图19
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图20
11. KEYENCE KV-N40AR R0 component supports Modbus function code 02; R500 component supports Modbus function codes 01, 05, and 15; DM component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图21
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图22
12. SCHNEIDER TM218LDAE40DRPHN supports function codes 01, 02, and 15 after firmware update I component supports Modbus function code 02; Q component supports Modbus function codes 01 and 15; M component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图23
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图24
13. Haiwei H40S2R X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图25
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图26
14. Wecon LX3V1212MT X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图27
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图28
15. Hollysys LE5109 I component supports Modbus function code 02; Q component supports Modbus function codes 01, 05, and 15; M component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图29
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图30
16. Taian AP-340BR-A X component supports Modbus function code 02; Y component supports Modbus function codes 01, 05, and 15; D component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图31
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图32
17. Rockwell 1766-L32BWA I component supports Modbus function code 02; Q component supports Modbus function codes 01, 05, and 15; N component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图33
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图34
18. Hexin CTH200 CPU H226L I component supports Modbus function code 02; Q component supports Modbus function codes 01, 05, and 15; V component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图35
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图36
19. Fuji SPENW0P40R-31 X component supports Modbus function code 02; Y component supports Modbus function codes 01 and 15; D component supports Modbus function codes 03 and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图37
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图38
20. Kinco K508-40AR I component supports Modbus function code 02; Q component supports Modbus function codes 01, 05, and 15; V component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图39
 
Common PLC register configuration examples for MThings (with accompanying diagrams)插图40
21. Siemens S7-1200 The I component supports Modbus function code 02; The Q component supports Modbus function codes 01, 05, and 15; The V component supports Modbus function codes 03, 06, and 16.
Common PLC register configuration examples for MThings (with accompanying diagrams)插图41
Common PLC register configuration examples for MThings (with accompanying diagrams)插图42

 

Put this resource to use in a real project?

Go to the Tool Center for message parsing, CRC verification and device debugging, or submit your requirements for selection and integration advice.

Engineer Membership

Turn this article into actionable debugging resources

After activation, you can use advanced message parsing, resource pack downloads, code examples, engineering cases and priority technical support, suitable for real project delivery.

Unlimited Advanced Tools
Resource & Code Packs
Complete Engineering Case Library
Priority Technical Support

Leave a Reply

Your email address will not be published. Required fields are marked *.