MODBUS ND06 Digital Integrated Current Transformer - Three phase Intelligent Power Monitoring/RS485 Communication

freeFree Technical Resource

This content is free to read, suitable for basic learning and search traffic.

MODBUS ND06 Digital Integrated Current Transformer - Three phase Intelligent Power Monitoring/RS485 Communication缩略图

Product Overview

MODBUS ND06is adigital integrated current transformer, which integrates the signal acquisition, analog-to-digital conversion, and digital communication of traditional current transformers (CTs) into a compact module. By using RS485 Modbus communication, digital current measurement values can be directly output without the need for the analog input module (ADC) of the PLC, greatly simplifying the wiring and configuration of the power monitoring system.

Comparison between Traditional CT and Digital CT

ComparisonTraditional CTND06 Digital CT
Output Signal0-1A or 0-5A AC CurrentRS485 Digital Signal, Directly Output Current Value (A)
Wiring complexityRequires ADC module+transmitterOnly 2 RS485 wires+power supply
Accuracy maintenanceAffected by long line transmission attenuationDigital signal lossless transmission
Data acquisitionRequires PLC/data collector ADC channelDirectly read by any Modbus master device

Technical specifications

  • Operating frequency: 50-400Hz (supports frequency converter output measurement)
  • Rated input1A-800A (multiple specifications available)
  • measurement range: 10%In - 130%In
  • precisionRatio difference ≤± 0.1%, angle difference ≤± 10 points
  • insulation: 2.5kV/1mA/1min
  • shellABS flame retardant material (UL94-V0 grade)
  • kernelNickel steel or nanocrystalline magnetic core
  • Communication: RS485 Modbus RTU

Applicable scenarios

  • Distribution cabinet power monitoringEach feeder circuit is equipped with an ND06 to collect current data from each circuit in a centralized manner
  • Motor operation monitoringMonitor the operating current of the motor, and trigger an alarm if it is abnormally high
  • Energy Efficiency AnalysisCooperate with HA or energy management system to track the electricity consumption of various devices

🛒 Purchase and Consultation

The MODBUS products introduced in this article can be purchased through official channels.

📍 Modbas Intelligence| 12th Floor, Tower A, Langqing Plaza, Guanyin Bridge, Jiangbei, Chongqing, China
📞 Phone:+86-023-65218879 | Duty phone:+86-17723047591
📧 Email: admin@modbus.com | 🌐 Official website:www.modbus.cn
📱 Search for "Modbus Debugging Assistant" on WeChat Mini ProgramModbus Debugging Assistantto learn more about product information

Put this resource to use in a real project?

Go to the Tool Center for message parsing, CRC verification and device debugging, or submit your requirements for selection and integration advice.

Engineer Membership

Turn this article into actionable debugging resources

After activation, you can use advanced message parsing, resource pack downloads, code examples, engineering cases and priority technical support, suitable for real project delivery.

Unlimited Advanced Tools
Resource & Code Packs
Complete Engineering Case Library
Priority Technical Support

Leave a Reply

Your email address will not be published. Required fields are marked *.