1、 Product Overview
Intelligent infrared controllerIt is a product that combines infrared remote control, status monitoring, and intelligencesignal communicationIntegrated industrial grade control equipment. Adopting imported components and patented technology design to supportRS485, BLE5.1Dual mode communication, compatibleModbus-RTUProtocol, available through WeChatMini programOrPLCConfigure to achieve remote control. Built in universalInfrared code libraryAnd with64The Road Learning Channel is widely used in scenarios such as smart hotels, industrial energy conservation, and intelligent buildings, providing a highly reliable integrated control solution for infrared devices.
2、 Technical parameters
| Category | Parameter details |
|---|---|
| Power input | DC 8V-28VWide voltage, supporting industrial grade power supply adaptation |
| Communication interface | RS485 (A/BTerminal) + BLE5.1Dual-mode communication |
| Protocol support | Modbus-RTUBluetoothBLE5.1agreement |
| Infrared emission | Onboard high-power infrared tube (accessible distance>5meters), supporting external extension cables |
| Storage capacity | 64Channel infrared learning storage, supports batch configuration |
| Control accuracy | supportNEC/RC-5Standard infrared code, real-time feedback on air conditioning status |
| Environmental adaptability | Industrial grade protection, rail mounted installation,-20℃~70℃Working temperature |
3、 Core functional highlights
- Omnipotent control
- Built in air conditioning/TV/set-top box infrared code library, direct control without learning
- Support fine adjustment of air conditioning temperature, mode, wind speed, etc
- External connectionZCTCurrent transformer, real-time monitoring of air conditioning on/off status
- Intelligent interconnection
- Dual channel communication:RS485 (Modbus-RTU)DockingPLC/Configuration system,BLE5.1Directly connect to WeChat mini program
- WeChat mini program one click network configuration, real-time debugging and code sending testing on mobile devices
- Efficient deployment
- 64Channel infrared waveform learning, supporting control of non-standard devices such as projectors and fans
- Batch reading/configuration function, suitable for rapid replication and deployment in multiple rooms
- Industrial grade design
- Wide voltage input (8V-28V), suitable for complex power environments
- Onboard Quick Test Key: Short press to send code test, long press for 3 seconds to enter automatic matching mode
4、 Installation and wiring instructions
Installation steps
- Mechanical fixation
- Usage standardDINInstall the guide rail buckle to ensure that the equipment is horizontally fixed
- Power connection
- AccessDC 8V-28VPower supply to
DC INTerminal (red wire+Vblack wire-GND)
- communication wiring
- RS485communication: connectionA+/B-to controller bus (recommended to use shielded twisted pair)
- Peripheral expansion:
IR LEDExternal infrared extension emission tubeZCTConnect current transformer (air conditioning status detection)STAStatus indicator light output

matters needing attention
⚠️ Be sure to disconnect the power before wiring
⚠️ RS485Bus requires terminal matching120ΩResistance (during long-distance communication)
5、 Communication protocol and debugging tools
1、 Communication protocol frame
1. Communication method:
UART Baud rate:9600 Data bit:8 Stop position:1 Checkpoint: None Flow control: none
Compliant Modbus-RTU Protocol format standard, address range 1-255.
2. Modbus-RTU Overview of the agreement
2.1 Read multiple register commands, suitable for function codes-03H
Host sends command:
| Address | Function code | Starting register address | Read the number of registers | Verification code (CRC16) | |||
| 1Byte | 1Byte | 1Byte | 1Byte | 1 Byte | 1 Byte | 1Byte | 1Byte |
| device address | function code value | high 8 bit | low 8 bit | high 8 bit | low 8 bit | low 8 bit | high 8 bits |
slave return information:
| address | function code | return data byte length | data 1 | data 2 | verification code ( N | device addressCRC16) | |||
| 1Byte | 1Byte | 1Byte | 1Byte | 1Byte | 1 Byte | 1 Byte | N Byte | 1Byte | 1Byte |
| function code value) | Function code value | N | High 8 Position | Low 8 Position | High 8 Position | Low 8 Position | ..... | Low 8 Position | High 8 Position |
2.2 Write a single register, suitable for function codes-06H
Host sends command:
| Address | Function code | Register address | Write data | Verification code (CRC16) | |||
| 1Byte | 1Byte | 1Byte | 1Byte | 1 Byte | 1 Byte | 1Byte | 1Byte |
| device address | function code value | high 8 bit | low 8 bit | high 8 bit | low 8 bit | low 8 bit | high 8 bit |
slave return information:
| address | function code | register address | write data | verification code (CRC16) | |||
| 1Byte | 1Byte | 1Byte | 1Byte | 1 Byte | 1 Byte | 1Byte | 1Byte |
| device address | function code value | high 8 bit | low 8 bit | high 8 bit | low 8 bit | high 8 bit | write multiple registers, applicable to function code 8 host sends command: |
2.3 address-10H
function code
| start register address | number of written data | write byte length) | Number of data written | Write byte length | data data data Verification code ( 1 | device address 2 | ... | function code value N | highCRC16) | ||||||
| 1Byte | 1 Byte | 1 Byte | 1 Byte | 1 Byte | 1 Byte | 1 Byte | 2 Byte | 2 Byte | ... | 2 Byte | 1 Byte | 1Byte | |||
| bit | low | bit 8 high | bit 8 low | bit 8 high | low 8 bit | 1-255 | high | low | high | high | ... | low | low | bit 8 bit | high 8 bit |
slave return information:
| address | function code | start register address | number of registers written | verification code (CRC16) | |||
| 1Byte | 1Byte | 1Byte | 1Byte | 1 Byte | 1 Byte | 1Byte | 1Byte |
| device address | function code value | high 8 bit | low 8 bit | high 8 bit | low 8 bit | high 8 bit | Bluetooth communication protocol 8 start symbol |
2.4 data length
| option field | message sequence number | user data segment | verification code ( | end symbol | fixedCRC16) | protocol data | |
| 2 Byte | 2 Byte | 1 Byte | 4 Byte | N Byte | 1 Byte | 1 Byte | 2 Byte |
| FF55H | Len | OPT | Sque | Data | CRC_H | CRC_L | FFAAH |
| total length, 0xFF55 | high bit before low) 8 Located at the back before , low 8 Located at the back | 08H-The representative needs to reply from the device 00H-The data chip representing Bluetooth transmission No response is required 04H-Representing data initiated by the chip itself Report, the chip needs to add its own unique feature Serial number reporting 18H-Representing transparent transmission of Bluetooth and serial data | Unique message sequence number | fill Modbus-RTU Number According to, reference Modbus-RTU Number According to the agreement | 8 digits high | Low 8 Position | Fixed 0xFFAA |
| 1. Bluetooth control command case: Turn off the air conditioning data testing protocol Bluetooth transmission:FF 55 00 15 08 01 02 03 04 A5 06 00 25 00 00 81 25 FD 81 FF AA Bluetooth return:FF 55 00 15 08 01 02 03 04 A5 06 00 25 00 00 81 25 FD 81 FF AA 2. Example of transparent transmission routine: reference register 3000H Serial port reporting data:A5 10 30 00 00 01 02 11 22 D0 DD Bluetooth received data:FF 55 00 0F 18 00 00 00 63 11 22 B4 82 FF AA Serial port reporting data:A5 10 30 00 00 01 04 11 22 33 44 01 5A Bluetooth received data:FF 55 00 11 18 00 00 00 02 11 22 33 44 BC A9 FF AA Bluetooth transmission of transparent data:FF 55 00 15 18 01 02 03 04 A5 06 00 25 00 00 81 25 0C 6B FF AA Chip string Output data:A5 06 00 25 00 00 81 25 Bluetooth transmission of transparent data:FF 55 00 11 18 00 00 00 02 11 22 33 44 BC A9 FF AA Chip serial port output data:11 22 33 44 | |||||||
3. Function code register table (adapted function code 03H, 06H, 10H)
| register content | register address | data type | read/write type | register value | description |
|---|---|---|---|---|---|
| firmware version number | 0000H | unsigned short integer | read-only | - | chip firmware version number |
| chip ID | 0001H | unsigned short integer | read-only | - | chip unique identifier |
| device address | 0002H | unsigned short integer | read-write | 1~255 | RS485 device address |
| communication baud rate | 0003H | unsigned short integer | read-write | 0-2400 1-4800 2-9600 3-14400 4-19200 5-38400 6-56000 7-57600 8-115200 9-128000 10-230400 11-156000 12-460800 13-500000 14-512000 15-600000 16-750000 17-921600 18-1000000 19-1500000 20-2000000 | serial communication baud rate (default 9600) . |
| MAC address | 0004H-0006H | unsigned short integer | read-only | - | 6 byte MAC address, occupied 3 register space). |
| retain | 0007H-0008H | Unsigned short integer | retain | - | Reserved registers, not recommended for use. |
| Chip reset | 0009H | Unsigned short integer | Can be written | - | Write a specific value to reset the chip. |
| retain | 000AH-000FH | Unsigned short integer | retain | - | Reserved registers, not recommended for use. |
| Air conditioning matching | 0010H | Unsigned short integer | Can be written | - | One key matching control register for air conditioning. |
| TV matching | 0011H | Unsigned short integer | Not currently supported | - | Not currently supported. |
| Set top box matching | 0012H | Unsigned short integer | Not currently supported | - | Not currently supported. |
| Fan matching | 0013H | Unsigned short integer | Not currently supported | - | Not currently supported. |
| Projector matching | 0014H | Unsigned short integer | Not currently supported | - | Not currently supported. |
| Matching with other devices | 0015H | Unsigned short integer | Not currently supported | - | Not currently supported. |
| Initiate infrared learning | 0016H | Unsigned short integer | Can be written | - | Activate infrared learning mode for recording 64 Channel infrared waveform. |
| Exit infrared learning | 0017H | Unsigned short integer | Can be written | - | Exit infrared learning mode. |
| Test infrared learning | 0018H | Unsigned short integer | Can be written | - | Test the learned infrared waveform. |
| Remote control NEC Send code | 0019H-001AH | Unsigned integer | Can be written | - | send out NEC Format infrared remote control code waveform. |
| Remote control RC-5 Send code | 001BH-001CH | Unsigned short integer | Can be written | - | send RC-5 Format infrared remote control code waveform. |
| Bluetooth room number | 001DH | Unsigned short integer | Can be written | - | Set the room number in the Bluetooth broadcast name. |
| AD Pin configuration | 001EH | Unsigned short integer | Can be written | - | to configure ADIN/RS485 Pin function. |
| AD Collecting power threshold configuration | 001FH | Unsigned short integer | Can be written | - | set up AD Collect power threshold, unit: 10mV. |
| Air conditioning code library code | 0020H | Unsigned short integer | Readable and written | - | Code library code for air conditioning matching. |
| TV code library code | 0021H | Unsigned short integer | Readable and written | - | Code library code for TV matching. |
| Set top box code library code | 0022H | Unsigned short integer | Readable and written | - | The code library code that matches the set-top box. |
| retain | 0023H-0024H | Unsigned short integer | retain | - | Reserved registers, not recommended for use. |
| Air conditioning power status | 0025H | Unsigned short integer | Readable and written | 0-close 1-Open | Air conditioning power status. |
| Air conditioning temperature status | 0026H | Unsigned short integer | Readable and written | 0-16℃ 1-17℃ ... E-30℃ | Air conditioning temperature status register. |
| Air conditioning mode status | 0027H | Unsigned short integer | Readable and written | 0-Automatic 1-Refrigeration 2-Dehumidification 3-Air supply 4-heating | Air conditioning mode status register. |
| Air conditioning speed status | 0028H | Unsigned short integer | Readable and written | 0-Automatic wind speed 1-A gust of wind 2-Second level wind 3-Three levels of wind | Air conditioning speed status register. |
| Air conditioning lighting status | 0029H | unsigned short | Readable and written | 0-Turn off the lights 1-Turn on the lights | Air conditioning lighting status register. |
| Air conditioning combination status (Specific instructions are provided below) | 002AH-002CH | Unsigned short integer | Readable and written | - | Air conditioning combination status control register. |
| TV power control | 002DH | Unsigned short integer | Readable and written | 00H-close 01H-Open | Code for the TV power button. |
| TV volume | 002EH | Unsigned short integer | Readable and written | 0-Volume reduction 1-Volume increase | TV volume control register. |
| TV channel | 002FH | Unsigned short integer | Readable and written | 0-Channel reduction 1-Channel addition | TV channel control register. |
| TV signal source | 0030H | Unsigned short integer | Readable and written | 0-Do not switch 1-Switch channels | Television signal source switching register. |
| TV return button | 0031H | Unsigned short integer | Readable and written | 0-Not executed 1-Execute return | TV return button switch register. |
| Set top box combination status | 0032H-0034H | Unsigned short integer | Not currently supported | - | Set top box combination status, currently not supported. |
| Set top box power supply | 0035H | Unsigned short integer | Readable and written | 00H-close 01H-Open | Set top box power status. |
| Set top box volume | 0036H | Unsigned short integer | Readable and written | 0-Volume reduction 1-Volume increase | Set top box volume control register. |
| Set top box channel | 0037H | Unsigned short integer | Readable and written | 0-Channel reduction 1-Channel Add | Set top box channel control register. |
| Set top box signal source | 0038H | Unsigned short integer | Readable and written | 0-Do not switch 1-Switch channels | Set top box signal source switching register. |
| Set top box return | 0039H | Unsigned short integer | Readable and written | 0-Not executed 1-Execute return | Set top box return button switch register. |
| Switching status of transformer equipment | 003AH | Unsigned short integer | Read only | 0-Shut down 1-Power on | External transformer equipment detects the on/off status of the equipment. |
| ADC Collect values | 003BH | Unsigned short integer | Read only | - | Read ADC The sampled value (representing voltage value: in units).10mV retain |
| Unsigned short integer | 003CH-003FH | retain | Reserved registers, not recommended for use. | - | Local code for air conditioning |
| Unsigned short integer | 0040H | Readable and written | Local code library code register. | - | Air conditioning control code |
| Unsigned short integer | 0041H | Readable and written | Instruction control code register. | - | Air conditioning power status |
| Unsigned short integer | 0042H | Readable and written | close | 0-Open 1-The air conditioner is in a single power state. | Air conditioning temperature status |
| Unsigned short integer | 0043H | Readable and written | Air conditioning temperature status register. | 16-31℃ | Air conditioning mode status |
| Unsigned short integer | 0044H | Readable and written | Automatic | 0-Refrigeration 1-Dehumidification 2-Air supply 3-heating 4-Air conditioning mode status register. | Air conditioning speed status |
| Unsigned short integer | 0045H | Readable and written | Automatic wind speed | 0-Automatic wind speed 1-A gust of wind 2-Second level wind 3-Three levels of wind | Air conditioning speed status register. |
| Air conditioning lighting status | 0046H | Unsigned short integer | Readable and written | 0-Turn off the lights 1-Turn on the lights | Air conditioning lighting status register. |
| retain | 0047H-0531H | Unsigned short integer | retain | - | Reserved registers, not recommended for use. |
| Infrared learning channel 1~62 | 0532H-114DH | Unsigned short integer | Readable and written | - | Allocation for each channel 100 Byte space. |
| Infrared learning channel 63 | 114EH-1180H | Unsigned short integer | Readable and written | - | Each infrared recording waveform occupies 100 One byte, occupied 50 A register. |
| Bluetooth transparent data register | 3000H | Unsigned short integer | Readable and written | - | Serial port reporting Bluetooth data transparent transmission format. |
CRC16Verification tool download:
This tool is used for quick calculationMODBUSIn communicationCRC16Verification value. Enter a hexadecimal data packet in the input box (every two characters represent one byte, and the number of characters must be even),Separate each byte with a space. After clicking on 'calculate', this calculator can calculate the length of the input data packet16Binary checksum.
CRC16Verify calculation tools
Resource price 1 point sales quantity328Release time2025February of the year16Daily update time2025April 8th of the year
Protocol Example:
Agreement description
The default address for this agreement is A5. The user needs to first set the address to A5 Conduct testing.
1. Set the device address
- send out:
FF 06 00 02 00 A5 FD AF - return:
FF 06 00 02 00 A5 FD AF
2. Firmware version number
- send out:
FF 03 00 00 00 01 91 D4 - return:
FF 03 02 00 01 90 53 - explainThe firmware version number is 0x0001.
3. ChipIDnumber
- send out:
FF 03 00 01 00 01 C0 14 - Return:
FF 03 02 50 56 2D AE - explain: ChipIDFor 0x5056.
4. Device from address register
- Set the address:
- send out:
FF 06 00 02 00 A5 FD AF - return:
FF 06 00 02 00 A5 FD AF
- send out:
- Obtain address:
- send out:
FF 03 00 02 00 01 30 14 - return:
FF 03 02 00 A5 51 EB - explainThe device address is: 0xA5.
- send out:
5. Serial communication baud rate setting register
Baud rate mapping table:
| Value | Baud rate |
|---|---|
| 0 | 2400 |
| 1 | 4800 |
| 2 | 9600 |
| 3 | 14400 |
| 4 | 19200 |
| 5 | 38400 |
| 6 | 56000 |
| 7 | 57600 |
| 8 | 115200 |
| 9 | 128000 |
| 10 | 230400 |
| 11 | 156000 |
| 12 | 460800 |
| 13 | 500000 |
| 14 | 512000 |
| 15 | 600000 |
| 16 | 750000 |
| 17 | 921600 |
| 18 | 1000000 |
| 19 | 1500000 |
| 20 | 2000000 |
- Obtain baud rate:
- send out:
A5 03 00 03 00 01 6D 2E - return:
A5 03 02 00 02 48 5C - explainThe baud rate is 9600.
- send out:
6. Air conditioning matching control register
- Matching air conditioning:
- send out:
A5 06 00 10 00 01 50 EB - Timeout return:
A5 06 00 10 80 03 B0 EA - Matching failed:
A5 06 00 10 80 03 B0 EA - Matching successful:
A5 06 00 10 00 4F D0 DF - explainMatch to code number 0x004F.
- send out:
7. Activate infrared learning mode
- Learning channel:
- send out:
A5 06 00 16 00 3F 31 3A - return:
A5 06 00 16 00 3F 31 3A - Learning completed:
A5 06 00 16 80 02 91 2B - Learning timeout:
A5 06 00 16 80 03 50 EB - Example:
- send out:
A5 06 00 16 00 00 71 2A - return:
A5 06 00 16 80 02 91 2B
- send out:
- send out:
8. Exit infrared learning mode
- send out:
A5 06 00 17 00 3F 60 FA - return:
A5 06 00 17 00 3F 60 FA
9. Test infrared learning waveform
- send out:
A5 06 00 18 00 3F 50 F9 - return:
A5 06 00 18 00 3F 50 F9 - Example:
- send out:
A5 06 00 18 00 00 10 E9
- send out:
10. Sending specified dataNECCode infrared waveform
- send out:
A5 10 00 19 00 02 04 00 FF 01 FE 95 DB - return:
A5 10 00 19 00 02 89 2B - explain: LaunchNECWaveform:
00 FF 01 FE.
11. Air conditioning code library code
- Set code number:
- send out:
A5 06 00 20 02 E4 90 0F - return:
A5 06 00 20 02 E4 90 0F
- send out:
- Obtain the code number:
- send out:
A5 03 00 20 00 01 9C E4 - Return:
A5 03 02 02 E4 C8 B6 - explainThe air conditioning code number is: 740.
- send out:
12. TV code library code
- Set code number:
- send out:
A5 06 00 21 00 03 80 E5 - return:
A5 06 00 21 00 03 80 E5
- send out:
- Obtain the code number:
- send out:
A5 03 00 21 00 01 CD 24 - return:
A5 03 02 00 03 89 9C - explainThe TV code number is: 3.
- send out:
13. Set top box code library code
- Set code number:
- send out:
A5 06 00 22 00 0B 71 23 - return:
A5 06 00 22 00 0B 71 23
- send out:
- Obtain the code number:
- send out:
A5 03 00 22 00 01 3D 24 - return:
A5 03 02 00 0B 88 5A - explainThe set-top box code number is: 11.
- send out:
14. Air conditioning status register - Combination state
- send out:
A5 10 00 2A 00 03 06 02 E4 AA 10 00 00 18 06 - return:
A5 10 00 2A 00 03 B8 E4
002A寄存器:空调代码号,高位在前 002B寄存器:高位相当于红外协议状态码1 低位相当于红外协议的状态码2 002C寄存器:高位相当于红外协议的按键码 低位参数为0使用指令中的代码号 参数为1使用本地代码号 返回:A5 10 00 2A 00 03 B8 E4
15. Air conditioning status register - Power status
- Control the air conditioning switch:
- send out:
A5 06 00 25 00 01 40 E5 - return:
A5 06 00 25 00 01 40 E5 - explainThe air conditioning is turned on.
- Turn off the air conditioning:
- send out:
A5 06 00 25 00 00 81 25 - return:
A5 06 00 25 00 00 81 25
- send out:
- send out:
- Obtain the power status of the air conditioner:
- send out:
A5 03 00 25 00 01 8C E5 - return:
A5 03 02 00 00 C9 9D - explainThe air conditioner is turned off.
- send out:
16. Air conditioning status register - Temperature status
- Control the air conditioning temperature:
- send out:
A5 06 00 26 00 0E F0 E1 - return:
A5 06 00 26 00 0E F0 E1 - explainThe air conditioning temperature is set to 30°C.
- send out:
- Obtain the temperature status of the air conditioner:
- send out:
A5 03 00 26 00 01 7C E5 - return:
A5 03 02 00 0E 48 59 - explainThe air conditioning temperature is: 30°C.
- send out:
17. Air conditioning status register - Mode status
- Control the air conditioning mode:
- send out:
A5 06 00 27 00 04 21 26 - return:
A5 06 00 27 00 04 21 26 - explainThe air conditioning mode is set to heating.
- send out:
- Obtain the air conditioning mode status:
- send out:
A5 03 00 27 00 01 2D 25 - return:
A5 03 02 00 04 C8 5E - explainThe air conditioning mode is: heating.
- Control the air conditioning mode(0: Automatic 1: Refrigeration 2Dehumidification 3: Air supply 4Heating)
- send out:
18. Air conditioning status register - Wind speed status
- Control the air conditioning speed:
- send out:
A5 06 00 28 00 03 50 E7 - return:
A5 06 00 28 00 03 50 E7 - explainThe air conditioning speed is set to Level 3.
- send out:
- Obtain the air conditioning speed status:
- send out:
A5 03 00 28 00 01 2D 25 - return:
A5 03 02 00 03 89 9C - explainThe air conditioning speed is: Level 3.
- Control the air conditioning speed(0: Automatic 1: Level 1 2: Level 2 3Level 3)
- send out:
19. Air conditioning status register - Lighting status
- Control the air conditioning screen display:
- send out:
A5 06 00 29 00 01 80 E6 - return:
A5 06 00 29 00 01 80 E6 - explainThe air conditioning screen display is turned on.
- send out:
- Obtain the display status of the air conditioning screen:
- send out:
A5 03 00 29 00 01 4C E6 - return:
A5 03 02 00 01 08 5D - explainThe air conditioning screen displays as: Open.
- send out:
20. TV status register - Power status
- send out:
A5 06 00 2D 00 01 C1 27 - return:
A5 06 00 2D 00 01 C1 27
21. TV status register - Volume status
- send out:
A5 06 00 2E 00 01 31 27 - return:
A5 06 00 2E 00 01 31 27 - Send TV volume code(1: Increase volume 0Volume reduction)
22. TV status register - Channel status
- send out:
A5 06 00 2F 00 01 60 E7 - return:
A5 06 00 2F 00 01 60 E7 - Send TV channel code(1Channel Add 0Channel reduction)
23. TV status register - Signal source status
- send out:
A5 06 00 30 00 01 51 21 - return:
A5 06 00 30 00 01 51 21
24. TV status register - Return status
- send out:
A5 06 00 31 00 01 00 E1 - return:
A5 06 00 31 00 01 00 E1
25. Set top box status register - Power status
- send out:
A5 06 00 35 00 01 41 20 - return:
A5 06 00 35 00 01 41 20
26. Set top box status register - Volume status
- send out:
A5 06 00 36 00 01 B1 20 - return:
A5 06 00 36 00 01 B1 20 - Send the volume code of the set-top box(1: Increase volume 0Volume reduction)
27. Set top box status register - Channel status
- send out:
A5 06 00 37 00 01 E0 E0 - return:
A5 06 00 37 00 01 E0 E0 - Send the channel code of the set-top box(1Channel addition 0Channel reduction)
28. Set top box status register - Signal source status
- send out:
A5 06 00 38 00 01 D0 E3 - return:
A5 86 01 C2 43 - explainThe set-top box has no signal source data.
29. Set top box status register - Return status
- send out:
A5 06 00 39 00 01 81 23 - return:
A5 06 00 39 00 01 81 23
30. Download air conditionerdpdata Data frame example:1 (0x0100-0x04bf)
The first frame
- Second frame:
A5 10 01 00 00 78 F0 03 45 29 2D 13 43 42 36 02 15 01 04 A2 AC A7 B5 B0 B1 B2 AD FF 05 A1 AE FF 07 A1 AE FF 06 A6 FF 08 A3 FF 03 AB B3 FF 02 A8 FF 00 A8 FF 01 8D 9D FF 00 FF FF 02 01 00 00 01 00 02 00 00 02 01 00 00 02 00 00 00 00 02 00 00 03 00 01 01 03 00 02 03 00 00 04 01 05 03 04 00 00 04 00 00 00 01 06 00 01 FF 02 00 FF 02 01 FF 02 31 FF 07 32 33 34 35 36 37 FF 06 B2 4D 00 00 00 00 06 B5 4A F5 00 00 00 06 B2 4D 7B 84 E0 1F 06 B2 4D 0F F0 E0 1F 06 B2 4D 6B 94 E0 1F 0C B2 4D E0 1F 03 FC B2 4D 00 00 00 00 12 B3 88 9A AA AA D7 B4 AA FF 40 66 FD B2 4D BF 40 D0 2F 00 00 11 11 30 1B 23 1B 6B A2 00 80 13 00 25 9D C0 FF FF FF FF FF 00 00 11 11 30 1B 23 1B 6B E0 00 80 13 00 25 9D C0 FF FF FF FF FF 00 00 11 11 30 1B 23 1B 6B 80 00 00 FF 98 1A - The third frame:
A5 10 01 78 00 78 F0 02 25 9D C0 FF FF FF FF FF 01 FF 0C 40 0B FF 06 C0 00 05 06 00 01 FF FF 0C 00 0B FF 04 C0 00 03 04 00 01 FF FF 0C 40 0B FF 0C C0 00 0B 0C 00 01 FF FF 0C 00 0B FF 0A C0 00 09 0A 00 01 FF FF 01 FF 01 FF FF 1E 20 03 FF BF 21 03 FF 9F 22 03 FF 5F 23 03 FF 3F 10 03 FF 1F 12 03 FF 1F 10 05 0C 08 12 05 0C 04 14 05 0C 0C 52 05 F0 10 53 05 F0 30 54 05 F0 20 55 05 F0 60 56 05 F0 70 57 05 F0 50 58 05 F0 40 59 05 F0 C0 5A 05 F0 D0 5B 05 F0 90 5C 05 F0 80 5D 05 F0 A0 5E 05 F0 B0 13 05 FC E4 20 08 FF 66 21 08 FF 28 22 08 FF 3C 23 08 FF 50 10 08 FF 65 12 08 FF 65 09 09 80 80 46 80 06 7F 00 81 06 7F 03 82 06 7F 07 83 06 7F 0B 84 06 7F 0F 85 06 7F 13 86 06 7F 17 87 06 7F 1B 88 06 7F 1F 89 06 7F 2B 8A 06 7F 27 8B 06 7F 2B 8C 06 D0 25 - The fourth frame:
A5 10 01 F0 00 78 F0 7F 2F 99 05 03 01 9A 05 03 01 9B 05 03 01 9C 05 03 01 90 03 1F 00 91 03 1F 03 92 03 1F 07 93 03 1F 0B 94 03 1F 0F 95 03 1F 13 96 03 1F 17 97 03 1F 1B 98 03 1F 1F 99 03 1F 03 9A 03 1F 07 9B 03 1F 0B 9C 03 1F 0F 9D 06 7F 7F 8D 05 03 03 20 03 E0 A0 21 03 E0 80 22 03 E0 40 23 03 E0 20 10 03 E0 00 12 03 E0 00 10 05 0C 08 11 05 0C 00 12 05 0C 04 13 05 0C 00 14 05 0C 0C 50 05 F0 00 51 05 F0 00 52 05 F0 10 53 05 F0 30 54 05 F0 20 55 05 F0 60 56 05 F0 70 57 05 F0 50 58 05 F0 40 59 05 F0 C0 5A 05 F0 D0 5B 05 F0 90 5C 05 F0 80 5D 05 F0 A0 5E 05 F0 B0 5A 06 80 80 5B 06 80 80 5C 06 80 80 5D 06 80 80 5E 06 80 80 20 08 FF 66 21 08 FF 28 22 08 FF 3C 23 08 FF 50 10 08 FF 65 12 08 FF 65 09 09 80 80 08 B0 05 FF A9 B1 05 FF A9 AD BF 65 - End frame:
A5 10 02 68 00 3B 76 05 FF A5 A7 05 FF AA B5 05 FF A3 A2 05 FF A2 AC 05 FF A2 B2 05 FF 86 17 20 09 FF BF 21 09 FF 9F 22 09 FF 5F 23 09 FF 3F 10 09 FF 1F 12 09 FF 1F 10 0B 0C 08 12 0B 0C 04 14 0B 0C 0C 52 0B F0 10 53 0B F0 30 54 0B F0 20 55 0B F0 60 56 0B F0 70 57 0B F0 50 58 0B F0 40 59 0B F0 C0 5A 0B F0 D0 5B 0B F0 90 5C 0B F0 80 5D 0B F0 A0 5E 0B F0 B0 12 0B FC E4 01 00 DF A2 - Download air conditioner:
A5 10 04 48 00 02 04 00 00 00 00 D3 CB
30.1data The first frame:dpSecond frame:2(0x2100-0x24bf)
- The third frame:
A5 10 21 00 00 78 F0 01 E2 17 05 02 15 16 14 01 79 01 00 A0 A1 AE B0 B1 A2 A3 A4 A5 A6 A8 A9 AC AD B2 B4 AA AB AF B3 FF FF 00 00 00 00 00 01 FF 14 A6 00 00 00 00 00 00 00 00 00 00 00 00 00 B5 00 00 00 00 00 BB BB BB 11 10 22 22 22 67 80 00 00 FF 00 33 00 C0 FF FF FF FF FF 09 40 0B FF 14 C0 00 0F 13 FF 09 00 0B FF 0E C0 00 01 0D FF 5E 20 06 E0 A0 21 06 E0 60 22 06 E0 40 23 06 E0 20 11 08 E0 20 12 08 E0 40 13 08 E0 C0 14 08 E0 80 01 05 40 40 07 05 80 80 51 02 F0 10 52 02 F0 20 53 02 F0 30 54 02 F0 40 55 02 F0 50 56 02 F0 60 57 02 F0 70 58 02 F0 80 59 02 F0 90 5A 02 F0 A0 5B 02 F0 B0 5C 02 F0 C0 5D 02 F0 D0 5E 02 F0 E0 31 02 0F 0C 32 02 0F 02 33 02 0F 04 34 02 0F 06 35 02 0F 08 36 02 0F 0A 37 02 0F 0F 41 03 F0 E0 42 03 F0 20 43 03 F0 05 F2 - End frame:
A5 10 21 78 00 78 F0 40 44 03 F0 60 45 03 F0 80 46 03 F0 A0 47 03 F0 C0 61 04 02 02 05 07 40 40 0F 07 80 80 03 09 80 80 0D 09 40 40 09 0B 08 08 8D 04 40 40 9D 04 20 20 6F 04 20 20 81 08 1F 01 82 08 1F 02 83 08 1F 03 84 08 1F 04 85 08 1F 05 86 08 1F 06 87 08 1F 07 88 08 1F 08 89 08 1F 09 8A 08 1F 0A 8B 08 1F 0B 8C 08 1F 0C 91 06 1F 01 92 06 1F 02 93 06 1F 03 94 06 1F 04 95 06 1F 05 96 06 1F 06 97 06 1F 07 98 06 1F 08 99 06 1F 09 9A 06 1F 0A 9B 06 1F 0B 9C 06 1F 0C A9 0D 7F 04 A1 0D 7F 02 AE 0D 7F 02 B0 0D 7F 03 B1 0D 7F 03 A7 0D 7F 19 A5 0D 7F 01 A6 0D 7F 09 A8 0D 7F 05 A0 0D 7F 06 A3 0D 7F 0B A2 0D 7F 08 B2 0D 7F 08 AC 0D 7F 16 AD 0D 7F 15 B4 0D 7F 07 AA 0D 7F 10 AB 0D 7F 0D AF 0D 7F 10 B3 0D 7F 0D 21 11 F0 C0 22 11 F0 80 23 11 F0 A1 30 - Room number (Bluetooth name)
A5 10 21 F0 00 01 02 40 01 B9 65 - Set room number
A5 10 24 48 00 02 04 00 00 00 00 4A 0A
测试指令: A5 10 00 2A 00 03 06 FF 02 AA 10 00 00 04 3D
31. send out
- return:
- Obtain room number:
A5 06 00 1D 03 E9 C1 96 - send out:
A5 06 00 1D 03 E9 C1 96
- Obtain room number:
- return:
- explain:
A5 03 00 1D 00 01 24 1B - The room number is:
A5 03 02 03 E9 08 E3 - ExplanationThe room number is 1001.
- explain:
32. Read and write learning data
- Read channel63Learning data:
- send out:
A5 03 11 4E 00 32 B8 10 - return:
A5 03 64 FA 56 67 00 4C E0 0C 00 00 71 0F 2B 39 98 04 69 09 8B 13 00 00 40 80 41 81 06 41 82 18 41 C1 40 83 41 C2 40 83 41 C3 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 FC 00 07 00 00 00 00 00 00 00 00 57 BA
- send out:
- Write channel63Learning data:
- send out:
A5 10 11 4E 00 32 64 B4 56 67 50 00 71 0D 00 00 71 2B 0E 00 77 04 92 09 00 20 00 00 40 80 41 81 41 82 1E 41 C1 40 80 01 41 C2 40 80 01 41 C3 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 4B B4 2F 2D 00 00 00 00 00 00 00 FC 12 - return:
A5 10 11 4E 00 32 3D D3
- send out:
33. to configurePB1Function
- set upPB1ForADtesting:
- send out:
A5 06 00 1E 00 00 F0 E8 - return:
A5 06 00 1E 00 00 F0 E8
- send out:
- obtainPB1Function:
- send out:
A5 03 00 1E 00 01 FD 28 - return:
A5 03 02 00 00 C9 9D - explainThe function is: 0.
- send out:
34. pairADVoltage (accuracy10mV)
- settingADvoltage is2V:
- send:
A5 06 00 1F 00 C8 A0 BE - return:
A5 06 00 1F 00 C8 A0 BE
- send:
- get setADvoltage:
- send:
A5 03 00 1F 00 01 AC E8 - return:
A5 03 02 00 C8 C8 0B - descriptionvoltage is 2V.
- send:
35. get switch status
- send:
A5 03 00 3A 00 01 BD 23 - return:
A5 03 02 00 01 08 5D - descriptionswitch status is on.
36. getPB1voltage
- send:
A5 03 00 3B 00 01 EC E3 - return:
A5 03 02 00 E5 08 16 - description: PB1voltage is 2.29V.
37. getMACaddress
- send:
A5 03 00 04 00 03 5D 2E - return:
A5 03 06 D8 2F E6 59 E8 7E 05 D7 - description: MACaddress is
D8:2F:E6:59:E8:7E.
38. Bluetooth control data testing
- turn off air conditioning data testing protocol:
- Bluetooth send:
FF 55 00 15 08 01 02 03 04 A5 06 00 25 00 00 81 25 FD 81 FF AA - Bluetooth receive:
FF 55 00 15 08 01 02 03 04 A5 06 00 25 00 00 81 25 FD 81 FF AA
- Bluetooth send:
39. Bluetooth transparent data testing
- serial port reporting data:
- send:
A5 10 30 00 00 01 02 11 22 D0 DD - Bluetooth receive:
FF 55 00 0F 18 00 00 00 63 11 22 B4 82 FF AA
- send:
- Bluetooth sends transparent transmission data:
- send out:
FF 55 00 15 18 01 02 03 04 A5 06 00 25 00 00 81 25 0C 6B FF AA - Chip serial port output:
A5 06 00 25 00 00 81 25
- send out:
Leave a Reply