Description
Product Overview
The four-way Modbus data center collector is a powerful device that can help you easily collect data from multiple Modbus devices. It has the following characteristics:
- Multi channel acquisition: Supports 4 RS485 communication ports and can simultaneously collect data from 4 Modbus devices.
- High speed cache: Built in cache with 1024 registers and 1024 coils, which can effectively improve data acquisition efficiency.
- Flexible configuration: Supports arbitrary modification of device address, register address, and coil address to meet your personalized needs.
- Stable and Reliable: Supports functions such as automatic polling and preemptive operating system to ensure the stability and reliability of data collection.
- Multiple applications: Suitable for various scenarios such as flow meter cluster collection, electricity meter cluster collection, industrial automation, etc.
Product Features
- Active Polling: Regularly scans all devices to ensure real-time data updates.
- Dataset: Consolidate all device data into one device for easy management and analysis.
- Preemptive operating system: ensures real-time and reliable data collection.
- 1024 register cache: stores large amounts of data, improves data acquisition efficiency.
- Supports device address remapping: Device addresses can be modified according to your needs for convenient networking.
- Supports register address remapping: Register addresses can be modified according to your needs for convenient data collection.
- Supports coil address remapping: The coil address can be modified according to your needs for convenient data collection.
- Supports multiple baud rates: Supports 1200~115200bps multiple baud rates, compatible with different devices.
- Supports multiple operating systems: Supports Win98/2000/2003/2008/CE/Linux/WinXP/Vista/Win7/Win8/Win10/Mac OS X and other operating systems.
Product Parameters
| Product Name | Number of Main Stations | Power Supply Voltage | Number of Slave Stations | Communication Baud Rate | Cache Size | Installation method | support system | Applicable Environment |
|---|---|---|---|---|---|---|---|---|
| Four channel Modbus data center collector | 1 piece | DC9V~DC35V | 4 of them | 1200~115200 | 1024 registers and 1024 coils | Support rail or fixed hole installation | Operating systems such as Win98/2000/2003/2008/CE/Linux/WinXP/Vista/Win7/Win8/Win10/Mac OS X | Operating temperature: -40 ℃~80 ℃, relative humidity: 5%~95% |
Product Application
- Flow meter cluster collection: It can simultaneously collect data from multiple flow meters for flow monitoring, analysis, etc.
- Meter Cluster Collection: It can simultaneously collect data from multiple meters for energy metering, analysis, and other purposes.
- Industrial Automation: capable of collecting data from production equipment for equipment monitoring, management, and other purposes.
Schematic:

Port Definition:

Product Advantages
- Efficiency Improvement: Can simultaneously collect data from multiple devices, effectively improving data collection efficiency. Simplified Programming: Supports arbitrary modification of device address, register address, and coil address, making it convenient for system developers to simplify programming.
- Simplified programming: Supports arbitrary modification of device address, register address, and coil address, making it convenient for system developers to simplify programming.
- Improve reliability: Support automatic polling, preemptive operating system and other functions to ensure the stability and reliability of data collection. Reduce costs: Only one device is needed to collect data from multiple devices, saving costs.
- Reduce costs: Only one device is needed to collect data from multiple devices, saving costs.
Precautions for use
- When configuring Modbus cache commands, the collector needs to work in the power on configuration state
- Before using the collector, it is necessary to clarify the data format of each device, including baud rate, data bits, parity bits, stop bits, etc;
- If there is a checksum configured in the communication settings, add 1 bit to the data bit. For example, if your device needs to be configured with 8 E, 1. The collector must be configured as 9 E, 1;
- Before collecting data from slave stations, it is necessary to list the device ID numbers, register addresses, and quantities of all slave devices that the master station needs to read or write, and configure them into the collector through the upper computer configuration assistant;
- After configuring the Modbus cache command correctly, the collector will actively contact the slave to obtain all data from the corresponding registers. If the cache command is not set correctly, the request for slave data will be unsuccessful or intermittent, which can be recognized by the slave indicator light;
- If the cache command is not set correctly, it may also cause the master device to not obtain the correct slave data;
- After the configuration is completed, the collector must be powered on again before it can work properly
- Due to the diversity of firmware versions, it is recommended to reset the serial port configuration after changing the collector instruction set each time;
- As long as the mobus instruction set setting prompt of the collector is successful, data can be collected normally. If the read command is not available or incomplete, it may be caused by software and system incompatibility, and can be ignored.
Common Problems and Solutions

If you need to collect data from multiple Modbus devices, the four-way Modbus data collector is your solution