10 inch intelligent touch panel - sends on/off light message, scene message, curtain switch, air conditioning control message

¥2,198.00

Product OverviewThe 10 inch smart touch panel is used to display status and control various RS485 devices. It executes pre-set functions through graphical butto

下单前需要咨询?
188-0105-4468
WeChat Customer Service二维码 扫码添加客服

描述

10 inch intelligent touch panel - sends on/off light message, scene message, curtain switch, air conditioning control message插图

Product Overview

The 10 inch smart touch panel is used to display status and control various RS485 devices. It executes pre-set functions through graphical buttons on the touch screen. Such as sending on/off light messages, scene messages, on/off curtains, air conditioning control messages, etc. to control other devices on the bus system.
Compared to ordinary button type panels, the 10 inch smart touch panel can display color images and emit prompt sounds through LCD, and can be easily and clearly operated through human-computer interaction interface.

Installation method

The 10 inch intelligent touch panel is mainly used in intelligent control systems and adopts a wall mounted installation method. It can be installed on 80 or 86 junction boxes10 inch intelligent touch panel - sends on/off light message, scene message, curtain switch, air conditioning control message插图1 10 inch intelligent touch panel - sends on/off light message, scene message, curtain switch, air conditioning control message插图2

Function Overview

  1. 10.1-inch color IPS, resolution 1280 * 800, capacitive touch screen design
  2. Supports software settings for vertical and horizontal display
  3. With switch, dimming, curtains, scene, value sending, switch indication functions
  4. Temperature controller function
  5. Air conditioning control
  6. Background music module control
  7. RGB, RGBW, RGBCW control and color temperature adjustment
  8. Fresh air and underfloor heating control
  9. Display air quality detection value
  10. Display energy monitoring value
  11. Weekly timer, users can modify the triggering time of the timer on the screen
  12. Scene group function
  13. Logic function, supports logic gate forwarding, threshold comparator, conversion of different data types
  14. Home navigation function
  15. Alarm function, built-in temperature sensor
  16. Time and date display, temperature display
  17. with security, screen saver and lock screen function, screen saver optional clock, logo

Technical parameters

– Working voltage:12V DCCommunication method:RS485 (maximum distance of 1200 meters)Communication baud rate:1200~921600bpsDisplay resolution: 1280 * 800– Storage space:128MbitFirmware upgrade method:SD cardOperating Temperature-20~+70℃Storage temperature:-30~+80℃Vibration test:10 to 25Hz (2G in X, Y, Z directions for 30 minutes)ESD testing:Air=± 8KV, Contact=± 6KV (can support higher)High and low temperature testing:70℃±3℃,72H/-20℃±3℃,72H; 50℃±3℃,90%±3%RH, 72HProduct dimensions:Appearance 275 × 170 × 7.5 mm; bottom box diameter 86 mm

General Function

General functions include system menu language selection, operation prompt sound, screen lock, screensaver, screen brightness adjustment, date/time display, etc.
In addition, the display style can be set to dark or light, the UI style of the multifunctional control page, and the status of sending day/night mode.

Homepage Navigation Function

Function page navigation keys can be set on the homepage to quickly jump to the function page, and multifunctional navigation keys can also be set to quickly execute a certain function in the multifunctional
.

Lighting Control

is mainly used for turning on and off lighting equipment or dimming lighting equipment. The dimming methods can be relative dimming, brightness dimming, relative+brightness dimming, or brightness+color temperature dimming. The color temperature dimming can be selected from ordinary control or direct control.

Curtain Control

is mainly used to control the opening and closing of curtains, roller blinds, and blinds. Support adjusting the position of curtains and the angle of blinds.

Value sending function

can send values of different data types.

Switch indication

is mainly used to indicate the switch status of lighting equipment or other devices.

Scene Control

Short operations are used to call scenes, while long operations can be set to store scenes.

Temperature Controller Function

The temperature controller is mainly used to control the room temperature, automatically and optimally controlling the heating and cooling according to the use of the room or the needs of the occupants.
Supports manual or automatic switching of heating/cooling control, supports three levels of wind speed and automatic wind speed control

Air conditioning gateway control

The air conditioning gateway control can be used to control VRV/VRF air conditioning systems, and needs to be coordinated with an RS485 to VRV/VRF air conditioning gateway for control. It supports functions such as air conditioning switch, set temperature, mode, air speed, swing, and timing control.

Background Music Control

is used to control the playback of background music, such as power on/off, play/pause, previous/next track, volume adjustment, mute, playback mode, etc.

RGB Dimming and Color Temperature Control

is mainly used for dimming three types of LED lights: RGB, RGBW, or RGBCW, using absolute dimming method. RGBCW supports adjustment of RGB lighting, color temperature, and brightness, with color temperature adjustment options available for either regular control or direct control.

Display air quality detection value

Temperature and humidity can be set PM2.5, PM10, CO2, VOC, AQI, The display of illuminance, wind speed, and rain conditions is obtained through external sensors.

underfloor heating control

automatically switches underfloor heating based on temperature difference. In addition, the scene and timing function of underfloor heating can be set, as well as the adjustable range of temperature setting
.

New air control

supports three levels of wind speed adjustment, on/off heat exchange, filter life counting, filter timeout alarm, and filter reset.
Automatically controls based on PM2.5 or CO2 concentration, and can also set scenarios.

Display energy monitoring values

can be set to display current, voltage, power, and energy (electrical energy), which can be obtained through other actuators or metering instrument gateways.

Weekly timing function

can send values of different data types at regular intervals, providing 3 timing controls After the timer function is enabled, the weekly timer in the screen settings interface can be operated, and the weekly timer can be turned off or on in this interface. In addition, the weekly timer can also be turned off through other devices on the bus.

Scene function

can set multiple messages to be sent in order of interval time, which can trigger N output messages.

Logical Function

Supports logical operations, including threshold comparison, format conversion, delay function, etc