MThings User Manual (Complete Version)

freeFree Technical Resource

This content is free to read, suitable for basic learning and search traffic.

MThings User Manual (Complete Version)

MThings User ManualManual usagePlease read this manual carefully before using this product. The content of the manual will be continuously updated and revised, but there may be occasional inconsistencies or errors with the actual use. Please feel free to leave us a message on the WeChat official account "MThings Technical Service" in a timely manner.

1 Software Overview

MThings is an upper computer software based on the MODBUS protocol stack, designed for operation and maintenance personnel in industrial control sites.MThings User Manual (Complete Version)Figure

2 Maintenance and installation

2.1 Download

Download link:http://gulink.cn/download

2.2 Installation

2.2.1 prepare

MThings User Manual (Complete Version)Figure1

Personal computer or server.

2.2.2 Install

1. Download the software package MThings_Pack.exe;

If the program fails to run normally after installation, please enter the installation directory, double-click the "VC_redist.x86.exe" file, and then reopen MThings.
3

Detailed function description

3.1 Basic Concepts

3.1.1 Device

Devices are communication nodes, and MThings includes two types: simulated master devices and simulated slave devices.Simulated host deviceWhen MThings serves as a host to connect multiple slave devices, users need to create a corresponding simulated host for each slave device in the software, and different simulated hosts are distinguished by device addresses.Figure 1 Schematic diagram of simulated host device MThings User Manual (Complete Version)Figure2 Simulate slave deviceWhen MThings is used as a slave to simulate data, users need to create different devices in the software based on different simulated slave addresses.

3.1.2 Data

In the MODBUS standard, four types ofdata blocksare defined:Table 1 MODBUS Data Definition

Data Block Unit Length Access Type Preamble Read Function Code
Coil Status 1 Bit RW 0 0X01
Discrete Input 1 Bit RO 1 0X02
Hold Register 2 Bytes RW 4 0X03
Input Register 2 Bytes RO 3 0X04

Based on the unit length of data blocks, four types of data blocks can be divided into two categories: Bit (BIT) data and Register (REG) data. Combining read and write attributes, the relationship between data blocks is as follows:Figure 2 Relationship between different data block types MThings User Manual (Complete Version)Figure3 Datais a specific definition within a data block, and data definitions in different data blocks are independent of each other.A data definition can contain multiple consecutive BIT/REG data addresses.The attributes of a piece of data include: the data block it belongs to, the data name, the data address, the data size, the data type (protocol type), the data coefficient (involved when floating-point data is transmitted in a fixed-point format), the byte order (involved when the register data size is 1, 2, or 4), and the word order (involved when the register data size is 2 or 4).

3.1.3 Transmission type and presentation type

MThings provides a user-friendly data visualization method, supporting the display of message data inactual business formats.Figure 3 Schematic diagram of intuitive visualization effect of equipment data MThings User Manual (Complete Version)Figure4When configuring data entry, MThings provides four parameters: transmission type, presentation type, coefficient, and unit. Their meanings are as follows:Table 2: Explanation of the meanings of relevant configuration parameters presented in the data

Presentation type
Register data type
Floating point type (FLOAT)
Rounding (Decimal System) (INT-DEC)
Register data type
Format (Hexadecimal) (INT-HEX)
Register data type supports data sizes of 2 and 4
Byte stream (BYTES)
Register data type
String (STRING)
BIT data type supports a data volume of 1
Bit data (BIT)
parameter Meaning
Transmission type Signed integer (INT), unsigned integer (UINT), floating point (FLOAT), byte stream (BYTES), bit data (BIT)
Presentation type Decimal integer (INT-DEC), hexadecimal integer (INT-HEX), floating point (FLOAT), byte stream (BYTES), string (STRING), epoch seconds (TIME)
Coefficient If the presentation data type is floating point and the transmission type is integer, it needs to be used with a coefficient. The software automatically multiplies the received data by the coefficient to convert it into floating point data for display
unit Description of auxiliary data meaning, directly presented on the interface

MThings supports the conversion between multiple transmission types and presentation types, with the corresponding relationships as follows:Figure 4: Conversion between Transmission Type and Presentation Type

Transmission Type
Signed integer (INT)
Unsigned integer (UINT)
Floating-point type (FLOAT)
Byte stream (BYTES)
Bit data (BIT)

3.1.4 Word order/byte order

In communication debugging,byte orderis a common concept, such as local byte order and network byte order. The MODBUS protocol also has the concept ofword order.Word orderrequires and explicitly states that the word order should be little-endian, meaning that when the original data is 0X12345678, the transmitted packet byte stream should be as follows:

3.2 Interface function partitioning

Figure 5 Schematic diagram of interface function partitionsMThings User Manual (Complete Version)Figure5

1. Main menu: Used to switch to the "main function page".

3.3 Configuration file management

3.3.1 Configuration data content

The configuration file contains complete configuration information for the MThings usage process, mainly including: link list, link parameters, device list, device advanced parameters, and data configuration.

3.3.2 Common Operations

Figure 6 Common Operations for Configuration FilesMThings User Manual (Complete Version)Figure6

1. New: Used to create a new project configuration file. For first-time use, you can skip creating a new configuration file

When multiple MThings software instances are opened and point to the same configuration file, the configuration data will be overwritten repeatedly, and the final content of the configuration file will be consistent with the content saved most recently.
It is prohibited to place configuration files within the software package path to prevent them from being mistakenly deleted during software upgrades!

3.4 Channel Management

Device
Data Configuration
Advanced Parameters
Device Type Device Address

MThings software supports establishing communication with the target device through serial ports, TCP connections, and UDP unicast.These three communication methods are collectively referred to as channels.Figure 7 Logical relationship between channels and devices

Device
data configuration
Device Type
Advanced Parameters
Device Address
Channel
Transmission Mode
Channel Type

3.4.1 Serial Port Channel

Figure 8 Serial Port Channel OperationMThings User Manual (Complete Version)Figure7

Access the channel management page through the "Channel" option in the auxiliary menu to view the list of serial ports actually present on the current PC. After MThings is launched, the serial port list will be automatically updated once. As shown in the figure above, the operations related to serial ports are as follows:Table 3: Definition of Serial Port Channel Status

channel status meaning
Closed The software has not enabled this serial port or it has been manually closed
Connected The software successfully opened and initialized the serial port
Fault The software failed to open the serial port. The reason may be that the serial port is occupied by other software or the set serial port parameters are invalid
Table 4 Definition of Serial Port Link Parameters
Parameter Meaning
Channel Name Operating System Allocation Information, non-editable
Transmission Mode Used to specify the type of transmission protocol running on the current serial port, with options available
character type When the transmission mode is set to "MODBUS-ASCII", this parameter specifies whether the protocol characters should be in uppercase or lowercase. The default is the uppercase format required by the standard protocol
Baud rate Supports 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200bps. Setting to other values will result in serial port opening failure
verification method Specify the data verification method in serial port bytes
data bit Specifies the number of data bits in the serial port byte data. If the data bits are required to be 7 bits in the MODBUS-ASCII protocol, please modify this parameter
stop bit Specify the length of the stop bit in the serial port bytes
Fluid control type No flow control by default, modify as needed based on actual application
If virtual serial ports are used, the master and slave device software should use paired serial ports

3.4.2 Network channels

Figure 9 Network channel operationMThings User Manual (Complete Version)Figure8

Access the channel management page through the "Channels" option in the auxiliary menu to view the list of network channels. When using for the first time, there are no network channels, and users need to create them according to their needs. As shown in the above figure, network-related operations such asTable 5: Definition of network channel status

channel status meaning
Closed The software has not enabled this link
Connected The network channel has been successfully chained
Connecting TCP client: Connecting to server
Fault TCP server: Local port is occupied
Table 6: Definition of network channel parameters
parameter meaning
Channel Name MThings are allocated uniformly and are not modifiable
Link mode Select MThings's role in the network layer, and choose from TCP client, TCP server, or UDP unicast
Re-establish link period (seconds) When the link mode is set to "TCP Client", by setting the reconnection period, MThings can be instructed to reconnect at specified intervals, which can simulate short links. The default period is 0, representing a long link.
Link idle protection When the link mode is set to "TCP Client" or "TCP Server", the link
duration After the connection is established, if there is no data interaction within the specified time period,
(seconds) MThings will proactively close the link.
Transmission mode Used to specify the type of transmission protocol running on the current link, selectable

(Synchronous)”, “MODBUS-TCP (Asynchronous)”Figure 10: Application method of TCP client connectionTCP server192.168.0.20, 502)

MThings
TCP client-1192.168.0.20Target port: 502
TCP client-2192.168.0.20Target port: 502
TCP client-3192.168.0.30Target port: 502

TCP server192.168.0.30, 502)Figure 11: Application method of TCP server link

MThings User Manual (Complete Version)Figure9This device: 192.168.0.20
TCP Client - 1
TCP client-2
MThings User Manual (Complete Version)Figure10This device: 192.168.0.30
TCP client-2
MThings
TCP server-1192.168.0.20
TCP server-2192.168.0.20
TCP server-3192.168.0.30
TCP server-4192.168.0.20
TCP client-1
Figure 12: Application method of UDP unicast link
MThings User Manual (Complete Version)Figure11This device: 192.168.0.20
UDP Unicast -1192.168.0.10Target port: 502
MThings User Manual (Complete Version)Figure12This device: 192.168.0.30
UDP unicast - 1192.168.0.10Target port: 503
MThings
UDP unicast -1192.168.0.20Target port: 502
UDP unicast -2192.168.0.30Target port: 502

3.5 system parameters

The system parameter page provides global control parameters for the MThings software, which users can modify during runtime and have them take effect immediately. The parameter values will be saved locally.Figure 13 System Parameter Page MThings User Manual (Complete Version)Figure13 Table 7 System Parameter Definitions

Parameter Meaning
Auto-start Function Switch, used to control whether MThings starts automatically with the operating system, disabled by default.
Historical Data Storage Interval Historical data function auxiliary parameter, used to control the interval time for refreshing and storing historical data.
Historical data is on the rise The historical data function has an auxiliary parameter. After the user configures this parameter, the header information will be printed and output along with the historical data report.
Data page refresh Function switch: To avoid wasting CPU computing resources, when users enable the "System" page for data browsing, they can use this switch to
Operation Mode supports both desktop and PAD modes, ensuring better display effects for the software across different terminals.

3.6 User Management

The user management page offers two types of users: administrators and end users. Administrators can perform all functions provided by MThings, while end users are only allowed to operate certain functions. The tuning and testing functions are not displayed, and they are prohibited from modifying device data, alarms, system configurations, etc.Table 8 User Permission Assignment

Page Administrator End User
System Page ✔ ✔
Historical Data Page ✔ ✔
Alarm Data Page ✔ ✔
Data Page ✔ ✔
Custom Page ✔ ✘
Statistics Page ✔ ✘
Auxiliary Page ✔ ✘
About Page ✔ ✔

The default password for administrators is none. When using MThings for the first time, the default is a password-less administrator account, which supports password modification by the administrator. Once the administrator sets a non-empty password, MThings will log in as the end user after restart. Users need to enter the administrator password to switch to the administrator user.Figure 14 User Management MThings User Manual (Complete Version)Figure14

3.7 Authorization Management

For commercial (paid) features in MThings, users need to obtain authorization before use. Before purchasing authorization, users need to enter the authorization management page to generate a machine identification code. After obtaining the authorization certificate, enter the authorization management page to import the certificate and activate the commercial features.Figure 15 Authorization Management MThings User Manual (Complete Version)Figure151. Upon clicking, a unique machine code will be automatically generated, which can be used to purchase an authorization certificate;

Reinstalling the operating system, replacing the disk, and other actions may cause changes to the system's key identification information, resulting in authorization failure and requiring the purchase of a new license. Operating systems that fail to properly obtain key system identification information will be unable to generate machine code, and thus will not be able to obtain authorization.

3.8 Device management

The device is a local image or service object of the communication debugging target device, and the device is responsible for everything

3.8.1 Add Device

Figure 16 Schematic of adding a deviceMThings User Manual (Complete Version)Figure16

1. Add device entry;0~255The starting address should be less than or equal to the ending address. By setting the starting and ending addresses, multiple devices can be added at once. If the starting address is equal to the ending address, it indicates that only one device is added.You can click "add" multiple times.

If the newly added device address already exists in the device list, it will not be created repeatedly. If a simulated master machine already exists in the link, adding a simulated slave machine is not allowed, and vice versa.

3.8.2 Remove device

Figure 17 Schematic of removing equipmentMThings User Manual (Complete Version)Figure17

1. Check the equipment that needs to be removed.

Removing the device will delete all data configuration information under it. Please proceed with caution! If the device is mistakenly removed, please reload the project configuration and remember not to save the current configuration.

3.8.3 View device information

Figure 18 Schematic diagram of device information viewingMThings User Manual (Complete Version)Figure18

1. Click the ">>" button, and the device list will automatically expand the page, displaying key device information: device type, device ID, channel, and device address.Table 9: Meaning of Device Name Status

Device name status meaning
Blue background [M]COM1-001 The current device is activated
Font color: red [M]COM1-001 The device stops running, the associated link is disconnected, or the device is disabled.
The above states can occur simultaneously.
Figure 19: Explanation of the meaning of device status identifiers.

FactoryMThings User Manual (Complete Version)Figure19After adding a device, MThings assigns a default name, and its format is described as follows:Figure 20: Meaning of the default device name format.

MThings User Manual (Complete Version)Figure20[M]COM1-001

[Device Type]: Link Name Device Address

3.8.4 Device disabled

If it is necessary to temporarily stop the operation of a device, the device can be disabled, instructing it to cease all operations and communications. Device disabling is often used to suspend the operation of a simulated slave device, simulating a device going offline.Figure 21 Schematic diagram of device disablement MThings User Manual (Complete Version)Figure211. Check the devices that need to be disabled, and double-click the "Sequence Number" header to select all.

Device disablement is only used as a temporary measure. During the device disablement period, if the link to which it belongs is disconnected and subsequently restored, the device will automatically recover.

3.8.5 Device recovery

Figure 22 Schematic diagram of device recovery operationMThings User Manual (Complete Version)Figure22

1. Check the device that needs to be recovered, and double-click the "Sequence Number" in the header to select all.

If the device you want to restore has its connection closed, clicking "Restore" will keep the device name in red. Once its connection status returns to "Connected", the device will automatically be restored.

3.8.6 Device attribute modification

For the created devices, it supports modifying key device attributes, including device name, associated link, and device address.Figure 23 Schematic diagram of device attribute modification MThings User Manual (Complete Version)Figure231. Double-click the device row that needs to be modified.

The device name cannot be empty and must be globally unique; otherwise, a modification failure prompt will be displayed. If the newly set affiliate link already has other device types, it will prompt a modification failure. If the newly set device address already exists on the associated link, a prompt will indicate that the modification has failed.
The added device does not support modifying the device type. If the type selection is incorrect when adding a device and a large amount of data configuration has already been completed, it is recommended to export the data template under the device, delete the incorrect device, add a device of the correct type again, and import the data template.

3.9 Device Data Configuration

Device data configuration involves converting MODBUS data protocol definitions into MThings configurations. After completing device data configuration, simple button operations can quickly initiate polling, batch read/write, and single read/write without manual packet assembly and data conversion. MThings supports intuitive visualization of protocol data information, which can significantly improve tuning and testing efficiency.

Before configuring device data, please confirm in the device list on the left whether the correct device to be configured has been selected.

3.9.1 Adding Data Configuration

Method 1:Figure 24 Schematic of Adding Data Configuration MThings User Manual (Complete Version)Figure241. Click the "Data" menu.

3.9.2 Delete data configuration

Figure 25 Schematic diagram of deleting data configurationMThings User Manual (Complete Version)Figure25

1. Click on the "ID" column to select the data configuration you wish to delete. Double-click the "ID" header to select all or cancel all selections.

After deleting data and clicking "Save" on the configuration file, the data configuration information will be lost. Please proceed with caution!

3.9.3 Edit Configuration Item

Table 10 Configuration Item Operation Instructions
Configuration Item Purpose & Configuration Method
ID Non-editable; the software assigns them sequentially.
Name Data Name, which can be defined arbitrarily and cannot be empty.
Value Non-editable; in operation mode,double-clickingcan trigger a single read-write operation.
Command Double-click to start editing. Enter the write command data to be issued. If there is no background color, it indicates that the data does not support the issuance of write commands.
Write In operation mode,double-clickto trigger the issuance of write commands.
Unit Data unit, which can be defined arbitrarily.
Range Data value range, used to assist in debugging, can be defined arbitrarily, and does not participate in the verification process.
Block After double-clickingthe cell, select to modify the data block type. Refer to the block definition for reference
Address Starting address of the current data item, no leading digits required.Note:Combined with the address offset in the advanced parameters, this address is the protocol (interface) address
quantity The number of consecutive data addresses currently occupied by the data item.

If the data item is an input register, it must not exceed 125.Note:The changes will take effect after MThings is restarted.

Transmission Type double-clickSelect and modify the data type defined in the MODBUS data protocol after the cell. For detailed instructions, please refer to Sectionin the data chapter.
Presentation Type Double-click thecell and select the data type presented in the modified software interface to achieve a more user-friendly experienceData chapterFestival.
decimal places If the presentation type is a floating-point number, this parameter takes effect; otherwise, it is forced to be 0.
endianness For registering data, if the data quantity is 1, 2, or 4, byte order needs to be specified. Please refer to the MODBUS data protocol requirements. If there are no special requirements, select big-endian.
Word order For registering data, if the data quantity is 2 or 4, the word order needs to be specified. Please refer to the MODBUS data protocol requirements. If there are no special requirements, select big-endian.
interval Used to control the interval time between read and write requests.
timeout period Used for simulating the host, it indicates the maximum allowable response delay for data read and write requests. If the delay exceeds this time, it is considered a timeout, and the next request is proceeded.

If data items are combined into one request with other data items, the timeout value should be the maximum among them.Figure 26 Schematic diagram of timeout and interval time for simulated host MThings User Manual (Complete Version)Figure26 Figure 27 Schematic diagram of the interval time for simulating the slave machine MThings User Manual (Complete Version)Figure27 Figure 28: Example of Bit Offset & Bit Count

The highest bit (Bit: 63)
Lowest bit (Bit: 0)

4 Reg (8 Bytes)MThings User Manual (Complete Version)Figure28 MThings User Manual (Complete Version)Figure29 MThings User Manual (Complete Version)Figure30 300001 MThings User Manual (Complete Version)Figure31 MThings User Manual (Complete Version)Figure32 300002 MThings User Manual (Complete Version)Figure33 MThings User Manual (Complete Version)Figure34 300003 MThings User Manual (Complete Version)Figure35 MThings User Manual (Complete Version)Figure36 MThings User Manual (Complete Version)Figure37 300004 MThings User Manual (Complete Version)Figure38 MThings User Manual (Complete Version)Figure39

Bit offset: 11
If too many curves are checked in the data configuration items, and the checked data undergoes high-frequency refreshing for a long period of time, it will inevitably lead to a continuous increase in computer memory. It is recommended to be cautious when associating too many data curves.

3.9.4 Batch editing configuration

If you need to quickly edit the "Name", "Unit", "Address", "Quantity", "Bit Offset", "Bit Count", "Factor", "Offset", and "Range" of data configuration, MThings supports users to copy multiple rows of Excel data and paste them into the designated position of the data configuration table.Figure 29 Example of batch filling configuration MThings User Manual (Complete Version)Figure40

3.9.5 Mark the background color of the data

Figure 30 Schematic of marking data background colorMThings User Manual (Complete Version)Figure41

1. long pressFor the "Name" cell of data that requires background color marking, the "Set Data Name Background Color" page will pop up.

3.9.6 Manual data sorting

You can rearrange the data configuration rows by dragging the "address" cell of the data.

Supports dragging to any position, either downwards or upwards. The data configuration row will be added above the row where dragging stops. To drag to the last row, you should drag the configuration row to a blank area in the table.
3.9.7

One-click data sortingFigure 31 Schematic of one-click data sorting MThings User Manual (Complete Version)Figure421. Double-click the "Sort" button to complete the one-click sorting function.MThings User Manual (Complete Version)Figure43The data blocks are sorted in the following order: coil status, discrete input, hold register, and input register.MThings User Manual (Complete Version)Figure44Within the same data block, sort by "data starting address" from small to large.MThings User Manual (Complete Version)Figure45When the data starting addresses are the same, they are sorted from small to large with reference to the "bit offset".MThings User Manual (Complete Version)Figure46When the bit offsets are the same, sort them from small to large with "bit number" as the reference.

3.9.8 Advanced parameter settings

The software provides advanced device parameter configuration for controlling public functions related to device reading and writing.Figure 32 Schematic diagram of advanced parameter settings for equipment MThings User Manual (Complete Version)Figure471. Click on the "Advanced Parameter Configuration" icon to enter the page.Table 11: Definition of Device Data Page Status

parameter Purpose & Configuration Method
Address offset Message data address = protocol (interface) data address + address offset.

Used to specify the display format of data addresses, with options of "Decimal" or "Hexadecimal". When "Hexadecimal" is selected, the address format is

By default, a write request for the status of a single coil is made using the 0X05 function code according to standard requirements.
Broadcasting equipment It is only used for simulating a host, indicating whether the current device is a broadcast device. If "Yes" is selected, all requests issued by the device will not wait for response messages.
Broadcast address -1 Only used for simulating a slave device and indicating the broadcast address, with a default value of 0.
Broadcast Address-2 Ditto
Immediately perform batch read after startup Only used for simulating the host, indicating whether to initiate a one-time or recurring batch read operation after the device link is established or the device resumes operation.
Immediately perform batch write after startup Only used for simulating the host, indicating whether to initiate a one-time or recurring batch write operation after the device link is established or the device resumes operation.
Advanced device parameters can be synchronously copied to other devices.

3.9.9 Copy Data Configuration

When multiple devices follow the same MODBUS data protocol, if the data configuration of one device has been completed, the current device data configuration can be fully copied to other selected devices through a copy operation.Figure 33 Schematic of Copying Data Configuration MThings User Manual (Complete Version)Figure481. Click the "Copy Configuration to Other Devices" icon button to enter the "Select Devices" page.

Data configurations can be copied between the simulated master and simulated slave.
Copying data configuration will overwrite the existing configuration of the target device. Please proceed with caution!

3.9.10 Create and export data templates

The data configuration workload in MODBUS is significant. To facilitate the transfer and sharing of data configurations, MThings supports the function of exporting data templates, making them independent of specific debugging environments, links, devices, and other differentiating factors. The recipient can quickly set up their own debugging environment through the data template, eliminating the need to reconfigure the data again.Figure 34 Schematic of creating and exporting data templates MThings User Manual (Complete Version)Figure491. Click the "Export" button to enter the "Export Device Data Configuration" page.Figure 35 Schematic of exported data template file MThings User Manual (Complete Version)Figure50

3.9.11 Import data template

Figure 36 Schematic of importing data templateMThings User Manual (Complete Version)Figure51

1. Click the "Import" button to enter the "Select Device Configuration Template File" page.

The simulated master and simulated slave can import each other's data templates, but it is recommended to carefully confirm the differences in data configurations between the two device types before proceeding.

3.10 Simulate data operations on host devices

3.10.1 Single data read

Figure 37 Schematic of Single Data Reading OperationMThings User Manual (Complete Version)Figure52

1. Double-clickto read the "Value" cell of the data row.double-clickThe "Numerical" header allows for batch reading of all rows of data at once.

When the device is disabled or the connection is closed, it will not be able to successfully initiate a single read. A single operation is not limited to a single register. If the data consists of multiple consecutive registers, it is also supported for a single operation.

3.10.2 Batch read (polling) data

Figure 38 Schematic diagram of batch data reading operationMThings User Manual (Complete Version)Figure53

1. Confirm the scope of data to be read in batch.

If you wish to initiate batch reading immediately after the device is started, you can modify the "Batch Read Immediately After Startup" option in the device's advanced parameters. If you need to change the data range for batch reading, please re-check the data combination for "Batch Reading". When the device is disabled or the link is closed, it will not be able to successfully initiate batch reading. After changes are made to the parameters related to "batch reading" on the device, a restart of polling is required for the changes to take effect.

3.10.3 Single data writing

Figure 39 Schematic diagram of single data writing operationMThings User Manual (Complete Version)Figure54

1. Double-clickto trigger the editing of the "instruction" cell, and enter the target value of the issued data.double-clickWrite button, immediately issue the command to write data.

Only the coil state and hold register support this operation. When the device is disabled or the connection is closed, it will not be able to successfully initiate a single write operation. A single operation does not necessarily refer to a single register. If the data consists of multiple consecutive registers, it is also supported for single operation.

3.10.4 Write data in batch

Figure 40 Schematic of batch write operationMThings User Manual (Complete Version)Figure55

1. Confirm the selected range for batch data writing.

Only the coil state and the hold register support this operation. If you wish for the device to initiate batch writing immediately upon startup, you can modify the "Batch Write Immediately After Startup" setting in the device's advanced parameters. When the device is disabled or the connection is closed, it will not be able to successfully initiate batch writing. After changing the parameters related to "batch write" on the device, a restart of "batch write" is required for the changes to take effect.

3.10.5 View data curve

If the curve is checked in the data configuration item and the data has been read and operated for a period of time, you can enter the "Data Curve Display" to view the changes in data values.Figure 41: Viewing the data curve diagram MThings User Manual (Complete Version)Figure561. Confirm the selected range of the data curve.

3.10.6 Parse message

To facilitate the analysis of response messages for read data and request messages for write data, MThings supports mapping BIT and register data from the original messages to a data table based on existing device data configurations. This eliminates the need for users to perform byte-by-byte analysis and calculation, allowing them to intuitively view the content of transmitted data.Figure 42 Schematic diagram of parsing message operation MThings User Manual (Complete Version)Figure571. Click the "Parse Message" button to open the parsing message input page.Figure 43 PDU Definition MThings User Manual (Complete Version)Figure58

3.10.7 Data search

When there are numerous data configuration rows and users need to quickly locate a specific data row, they can scroll to the designated position in the table quickly by searching for the data name.Figure 44 Schematic diagram of data search operation MThings User Manual (Complete Version)Figure591. Enter a partial keyword (case-sensitive) in the name of the data to be searched.Figure 45 Schematic diagram of widening row height operation MThings User Manual (Complete Version)Figure601. Click on the cell in the "Name" column to increase the height of the current row.

If there are multiple matches, the user can click the search button multiple times, and the search function will continue to traverse other rows in the table and identify matching items. The search scope only includes the "Name" column.

3.10.8 Data Filtering

The data page provides multiple methods for filtering information, facilitating users to focus on key information more quickly and effectively.Figure 46 Schematic diagram of data filtering MThings User Manual (Complete Version)Figure611. Clicking the "Filter Blocks" button can hide/display specified data block types.

The operation of filtering blocks is only a temporary action. After restarting the software, all blocks will be redisplayed. The operations of filtering rows and columns will store the configuration file, and the display/hide status of the last selection will be retained after restarting the software.

3.11 Simulate data operation of slave devices

The process of simulating the response from the slave device data does not require manual triggering. Upon receiving a request from the master, the software automatically packages and responds. The simulated slave also supports data curves and parsing of messages. For operation methods, refer to the previous chapter.Figure 47 Schematic diagram of preset simulation data method MThings User Manual (Complete Version)Figure621. Double-click the "Value" cell that requires simulated data to open the "Select Simulated Data Method" page.

You can drag a row of "numeric" cells to another row of "numeric" cells to quickly copy simulated data configurations.
Table 12: Definition of parameters for simulated data method
parameter Usage & Configuration Method
Strategy Define simulation method, default is fixed value
Refresh interval (ms) Interval for numerical update, during which the value remains unchanged.
Time axis starting point Define the origin position of the curve time axis.
Upper and lower limits of random interval Based on existing curve values, when a valid random interval is defined, random numbers within the range are superimposed. If the upper and lower limits are the same, it represents no randomness.
Maximum/minimum value Based on existing curve values, when a valid extreme value range is defined, the curve values will be constrained within this range, which can generally be used for curve peak shaving and filling
Table 13: Configuration of Slave Register Data Strategy
Strategy Usage & Configuration Method
Fixed Value / Linear / Parabolic Refer to the description in the software interface
/ Sine Curve / Square Wave
Preset Data MThings User Manual (Complete Version)Figure63Each piece of data is separated by a newline character;MThings User Manual (Complete Version)Figure64Supports copying entire columns of data from Excel to the data window;MThings User Manual (Complete Version)Figure65When the refresh interval is set to 0, requests from the host are replied to in a row-by-row manner;MThings User Manual (Complete Version)Figure66When the software is restarted or the round-robin reading is reinitiated, the data reply will also be reset.
Association Mode Associate any data from other simulated hosts to integrate key information and forward it to northbound devices.

3.12 Data Curve Display

The Data Curve Display is a container for multiple data curves, serving multiple important functional areas. Each curve represents a legend, and the display provides legend customization, data statistics, and export functions.

3.12.1 Curve Viewing

Figure 48 Schematic of Curve ViewingMThings User Manual (Complete Version)Figure67

The curve view includes a list of data curves (legends) and a legend display area. The legend list on the left contains legends in the display state, with the background color matching the curve color. The legend display can show multiple legends simultaneously. By default, different legends are associated with the left Y-axis, but some legends can be configured to be associated with the right Y-axis.

3.12.2 Maintain the legend

Figure 49 Schematic diagram of maintenance legendMThings User Manual (Complete Version)Figure68

1. Click the "Maintain Legend" button to open the legend editing page.

3.12.3 Coordinate axis management

The data curve displayer supports multiple modes for viewing data curves, including: normal mode, fixed mode, and oscilloscope mode.Figure 50 Axis parameters MThings User Manual (Complete Version)Figure69 Table 14 Definition of coordinate axis parameters

Parameter Purpose & Configuration Method
Update Interval (ms) Controls the data refresh interval of the curve displayer.
Time Axis Mode Switches the time axis display mode.
Maximum Duration (Hours) Controls the maximum retention time for all data in the curve. After exceeding this time, the curve data will be automatically removed.
Window Duration (Seconds) Takes effect in the "Oscilloscope" mode of the time axis, specifying the length of the time axis that can be displayed. This value should be less than the "Maximum Duration" parameter.
Left Y-Axis Adaptation Controls whether the left Y-axis automatically adjusts with the curve data range.
Right Y-axis Adaptation Controls whether the right Y-axis automatically adjusts with the curve data range.
Left Y-axis Warning Line 1 Switch
Left Y-axis Warning Value 1 Displayed as a dashed line on the curve displayer according to the set value
Left Y-axis Warning Line 2 Switch
Left Y-axis Warning Value 2 Displayed as a dashed line on the curve displayer according to the set value
Right Y-axis Warning Line 1 Switch
Right Y-axis Warning Value 1 Displayed as a dashed line on the curve displayer according to the set value
Right Y-axis Warning Line 2 Switch
Right Y-axis Warning Value 2 Displayed as a dashed line on the curve displayer according to the set value

3.12.4 Data Export

Figure 51 Data Export DemonstrationMThings User Manual (Complete Version)Figure70

1. Click the "Export" button, select the path to store the exported data, and you're done.

The exported data file contains all curve data in csv format, which can be directly opened using EXCEL.

3.12.5 Filter Devices

If there are too many data curves, to facilitate viewing all data curves under the same device, you can use the device filtering function to hide data curves that are not needed for the moment (legend).Figure 52 Schematic of Filtering Device MThings User Manual (Complete Version)Figure711. Click the "Filter" button to open the device filtering page.

3.13 Channel message management

As channel messages serve as crucial debugging information, MThings provides a comprehensive and user-friendly approach for message management.

3.13.1 View channel messages

Figure 53: Schematic diagram of viewing channel messagesMThings User Manual (Complete Version)Figure72

1. By default, the software does not enable the message browsing window. To enable it, you need to check "Message", and then the message window will be embeddedTable 15: Definition of Message Colors

color meaning
blue Send messages normally
Green Normal received message
Red Abnormal message
Purple Link status event
For user identification, when receiving a MODBUS-TCP message, the first 6 bytes of the MBAP, including the sending sequence number, protocol type, and data length, are enclosed in a pair of "[ ]" during message display.

3.13.2 Channel message control

Figure 54 Schematic of channel message controlMThings User Manual (Complete Version)Figure73

1. By default, the software starts receiving all link messages upon startup. Checking the "Receive" option allows you to enable or disable message reception.

After filtering the links, the filtered messages will not be saved. Scheduled or manual clearing will not affect the saved data.

3.13.3 Serial port packet capture

To perform serial port packet capture, simply create any simulated host device within the target serial port connection,

It is not recommended to use MThings for serial port packet capture. It is advisable to choose a general-purpose serial port tool.

3.14 system data

The system data page provides configuration functionality, enabling users to flexibly and intuitively display and manipulate data based on existing device data. This feature requires authorization to use.Figure 55 Schematic of system data page MThings User Manual (Complete Version)Figure74

3.14.1 Enter configuration editing

Figure 56: Schematic of entering configuration editingMThings User Manual (Complete Version)Figure75

3.14.2 Exit configuration editing

Double-click the system data canvas again to exit the configuration editing.

3.14.3 Overall page parameters

After entering the configuration editing mode, the "Page Parameter Settings" dialog box will automatically pop up, allowing users to modify the overall page parametersTable 16 Overall Parameter Definition for Page

Parameter Purpose & Configuration Method
Title Controls the display of the title content in the center of the canvas header.
Background Color If the canvas has no background image, you can double-click this parameter to fill it with a uniform background color.
Canvas Width Controls the width of the display area of the canvas, with the value in the same unit as the resolution.
Canvas Height Controls the height of the display area of the canvas, with the value in the same unit as the resolution.
Canvas Background Image Set a user-defined background image. After double-clicking in the parameter area, select the path of the background image. The image should be in .png format.

3.14.4 Add graphic control

Figure 57: Adding a Graphic ControlMThings User Manual (Complete Version)Figure76

The process of adding a graphical control involves completing four configuration steps:Drag inIn the canvas;

3.14.5 Modify graphical controls

After entering the configuration editing mode, clicking on an existing graphical control will result in the appearance of a blue wireframe. Users can quickly resize the graphical control by dragging it with the mouse.Figure 58 Modify Graphic Control MThings User Manual (Complete Version)Figure771. Adjust the alignment of the selected control

3.14.6 Control description

Name Effect diagram Function description
Data label MThings User Manual (Complete Version)Figure78 MThings User Manual (Complete Version)Figure79Display data name, value, and unit;MThings User Manual (Complete Version)Figure80After double-clicking, edit the value and issue a command;MThings User Manual (Complete Version)Figure81Support multiple name and value layout methods.
Static text Annotation information MThings User Manual (Complete Version)Figure82Display static text information;MThings User Manual (Complete Version)Figure83Font size and color can be set.
Multi-row table MThings User Manual (Complete Version)Figure84 MThings User Manual (Complete Version)Figure85Display data from multiple different devices.
During the daytime MThings User Manual (Complete Version)Figure86 MThings User Manual (Complete Version)Figure87, the local time is displayed.
Page tabs MThings User Manual (Complete Version)Figure88 MThings User Manual (Complete Version)Figure89allow for switching between different interface information displays by clicking on different page tabs.
Slider MThings User Manual (Complete Version)Figure90 MThings User Manual (Complete Version)Figure91provides a quick way to adjust numerical parameters using a slider;MThings User Manual (Complete Version)Figure92supports floating-point instructions;MThings User Manual (Complete Version)Figure93allows for customization of control background and numerical colors.
Device status MThings User Manual (Complete Version)Figure94 MThings User Manual (Complete Version)Figure95displays the communication status of devices in the associated device list.
MThings User Manual (Complete Version)Figure96
Switch MThings User Manual (Complete Version)Figure97 MThings User Manual (Complete Version)Figure98visually displays the state quantity;MThings User Manual (Complete Version)Figure99Users can manually trigger the issuance of switch statuses;MThings User Manual (Complete Version)Figure100Supports custom status values (other than 0/1).
Separator MThings User Manual (Complete Version)Figure101Separator for auxiliary control classification display.
Flow line MThings User Manual (Complete Version)Figure102 MThings User Manual (Complete Version)Figure103Based on the base map pipeline, adds dynamic flow direction effects;MThings User Manual (Complete Version)Figure104Supports adjusting line color and width;MThings User Manual (Complete Version)Figure105Supports multiple turning points;MThings User Manual (Complete Version)Figure106Supports triggering flow or stillness based on associated device data.
Electricity MThings User Manual (Complete Version)Figure107 MThings User Manual (Complete Version)Figure108Displays remaining electricity data;MThings User Manual (Complete Version)Figure109Supports defining data range and refresh step size;MThings User Manual (Complete Version)Figure110Supports defining alert values and automatically matching alert colors.
Graphic switch MThings User Manual (Complete Version)Figure111 MThings User Manual (Complete Version)Figure112Intuitively displays state values;MThings User Manual (Complete Version)Figure113Multiple switch styles;MThings User Manual (Complete Version)Figure114Users can manually trigger the issuance of switch states;MThings User Manual (Complete Version)Figure115Supports custom state values (not limited to 0/1).
Dashboard MThings User Manual (Complete Version)Figure116 MThings User Manual (Complete Version)Figure117Intuitively displays value names, values, and units;MThings User Manual (Complete Version)Figure118Supports adjusting range, display precision, and units;MThings User Manual (Complete Version)Figure119Supports modifying value colors.
Speedometer MThings User Manual (Complete Version)Figure120 MThings User Manual (Complete Version)Figure121Intuitively displays value names, values, and units;MThings User Manual (Complete Version)Figure122Supports adjusting range and units;MThings User Manual (Complete Version)Figure123Supports modifying numerical color;MThings User Manual (Complete Version)Figure124LCD code presents integer data.
Progress dial 1 MThings User Manual (Complete Version)Figure125 MThings User Manual (Complete Version)Figure126Visually displays absolute value and percentage of data;MThings User Manual (Complete Version)Figure127Supports adjusting actual data range.
Progress dial 2 MThings User Manual (Complete Version)Figure128 MThings User Manual (Complete Version)Figure129Visually displays relative range percentage of data;MThings User Manual (Complete Version)Figure130Supports adjusting actual data range.
Compass MThings User Manual (Complete Version)Figure131 MThings User Manual (Complete Version)Figure132Visually displays angle data (0~360);MThings User Manual (Complete Version)Figure133Supports floating-point data.
Thermometer MThings User Manual (Complete Version)Figure134 MThings User Manual (Complete Version)Figure135Visually displays temperature data;MThings User Manual (Complete Version)Figure136Supports customizable range;MThings User Manual (Complete Version)Figure137Supports negative temperatures;MThings User Manual (Complete Version)Figure138Supports floating point numbers;MThings User Manual (Complete Version)Figure139Supports modification of scale color.
Background image MThings User Manual (Complete Version)Figure140 MThings User Manual (Complete Version)Figure141Used for locally adding image display;MThings User Manual (Complete Version)Figure142Supports importing images from any local path;MThings User Manual (Complete Version)Figure143Supports commonly used image file formats.
Real-time curve MThings User Manual (Complete Version)Figure144 MThings User Manual (Complete Version)Figure145Displays up to 3 sets of data curves simultaneously;MThings User Manual (Complete Version)Figure146Supports modifying the display time range;MThings User Manual (Complete Version)Figure147Can display up to 24 hours of data;MThings User Manual (Complete Version)Figure148Supports modifying the colors of curves and coordinate axes.
Historical curves MThings User Manual (Complete Version)Figure149 MThings User Manual (Complete Version)Figure150Displays a historical data curve;MThings User Manual (Complete Version)Figure151Supports modifying the display time range;MThings User Manual (Complete Version)Figure152Can display up to 180 days of data;MThings User Manual (Complete Version)Figure153Supports modifying the colors of curves and coordinate axes.
Alarm summary MThings User Manual (Complete Version)Figure154 MThings User Manual (Complete Version)Figure155Window displays all active alarms;MThings User Manual (Complete Version)Figure156Supports dynamic display changes.
Alarm statistics MThings User Manual (Complete Version)Figure157 MThings User Manual (Complete Version)Figure158Display key statistical data for activity alarms;MThings User Manual (Complete Version)Figure159Automatic alarm correlation function.

3.15 Historical data

The historical data page provides persistent storage, display, printing, and export functions for device data, and supports generating independent data files daily, as well as statistical data summary information. This function requires authorization for use.Figure 59 Schematic diagram of associated device data storage MThings User Manual (Complete Version)Figure160The operation of historical data is strongly associated with device data. Users need to first check the "Store" option for the data items to be stored on the "Data" page.

To avoid frequent modifications to storage configurations, it is recommended to debug the data configuration until it is stable before enabling the historical data storage function. Any changes to the configuration related to historical data require a software restart!
Figure 60 Schematic diagram of historical data functionMThings User Manual (Complete Version)Figure161

Refreshing the historical data display table: The backend historical data will not automatically update the table on the page. If you remain on the current page for an extended period, you will need to manually click the "Refresh" button to view the latest historical data records.

3.16 Data gateway

The data gateway function provides protocol conversion and data aggregation capabilities, enabling bidirectional conversion of different channel types, protocol types, device addresses, register addresses, data blocks, data types, and data lengths. This function requires authorization for use.Figure 61 Schematic Diagram of Data Flow in Transparent Transmission Mode MThings User Manual (Complete Version)Figure162 Figure 62 Schematic Diagram of Data Flow in Caching Mode MThings User Manual (Complete Version)Figure163 3.16.1 Application of Transparent Transmission ModePreparatory work:1) Create a simulated host in MThings and connect it to a southbound serial device;Figure 63 Device configuration in transparent transmission mode MThings User Manual (Complete Version)Figure164 1. double-clickNewly established slave device.double-clickAfter binding the mode, select the transparent transmission mode.double-clickBind the device.

In transparent transmission mode, the slave device can be configured without device data.

3.16.2 Cache mode application

MThings supports associating two different devices (simulated slave and simulated master) through cache mode to achieve channel, protocol, and device address conversion functions.Preparation:1) Create a simulated master device in MThings and connect it to a southbound serial device;Figure 64 Cache mode configuration and device binding MThings User Manual (Complete Version)Figure165 1. double-clickFrom the machine equipment.double-clickBinding mode.

In the caching mode, the slave device can be configured without device data, but its associated simulated master device should be configured with valid data and initiate polling. In caching mode, if the request data from the northbound device exceeds the configuration of the southbound device, zeros will be automatically padded.

3.17 Alarm Data

The alarm data page provides functions such as device alarm generation, storage, configuration, display, export, and voice prompts. It supports the generation of alarm information based on multiple conditions and across devices, referring to the standard: "IEC 62682:2014"Figure 65 Schematic diagram of alarm data function MThings User Manual (Complete Version)Figure1661. Switch the alarm record type. The active alarms are divided into two categories: "Need to Confirm" and "No Need to Confirm"Figure 66 Schematic diagram of alarm configuration function MThings User Manual (Complete Version)Figure1671. Add a new alarm configuration.Table 17: Parameter definitions for the alarm information configuration table

parameter Purpose & Configuration Method
Name Specify the alarm name.
Type Select the type of the current configuration based on the pre-configured alarm type table.
Level Optional: Important, Minor, Warning.
Voice Warning Checking the option will trigger different voice warnings based on the fault level.
Manual Confirmation Specify whether the current alarm configuration requires user confirmation.
Generation Delay (seconds) To prevent alarm chatter, set the alarm generation delay. An active alarm record can only be generated when the alarm condition persists for this duration.
Recovery Delay (seconds)
Recovery delay (seconds) To prevent alarm chatter, set the alarm recovery delay. An active alarm can only be marked as recovered when the alarm condition does not persist for this duration.
Condition 1 Alarm Triggering Condition 1
Relationship Logical Relationship between Alarm Triggering Conditions 1 and 2
Condition 2 Alarm Triggering Condition 2
Relationship Logical Relationship between Alarm Triggering Conditions 2 and 3
Condition 3 Alarm Triggering Condition 3
Table 18 Alarm Condition Configuration Table Parameter Definition
Parameter Purpose & Configuration Method
Enable Turn on this switch after enabling the trigger condition.
Device Select the associated device.
Data Select the associated device data.
Trigger Mode Select the trigger type, options include: greater than, greater than or equal to, equal to, not equal to, less than or equal to, less than, between, not between.
Threshold 1 The threshold for conditional judgment that matches the trigger mode.
Hysteresis 1 The magnitude of the return difference when the condition is not met.
Threshold 2 Only applicable to triggering modes of "between" and "not between".
Return difference 2 Only works with the triggering methods of "between" and "not between".

3.18 Custom request

MThings supports users in sending custom messages based on the created simulated host devices, and the messages must comply with the MODBUS protocol requirements.

The custom request function is exclusively for the simulated host, and can be accessed using either standard function codes or custom function codes. Before customizing the request operation, please confirm on the left device list whether the current device is correct.
Figure 67 Schematic diagram of custom request operationMThings User Manual (Complete Version)Figure168

1. Click on the "Customization" main menu to enter the customization request page.

3.19 Message statistics

MThings supports synchronous statistics of message interaction data during the communication interaction process between simulated master devices and simulated slave devices.Figure 68 Schematic diagram of statistical operation MThings User Manual (Complete Version)Figure1691. Click on the "Statistics" main menu to access the statistics page.Table 19 Definition of statistical data items

data meaning
Sent normally Successfully sent to the link
Received normally Received a normal host request or slave reply data
packet loss rate Only applicable to analog hosts
Send failed Due to an abnormal link, data could not be sent
Response abnormal The slave device replied with an abnormal frame (request function code + 0X80)
Response timeout Did not receive a normal response frame from the slave device
Frame length abnormal The received data could not be parsed normally
Checksum abnormal The received message has the following check sum error:
Device communication messages are required during the statistical process, and packet capture process statistics are not supported. If there are abnormal messages in the link and their corresponding device addresses cannot be identified, such abnormal messages will be classified as belonging to "other" devices. It is recommended to store the original messages synchronously during the statistical process to facilitate problem analysis.

3.20 Auxiliary tools

MThings, as a commonly used MODBUS testing tool, provides multiple auxiliary tools to assistFigure 69 Schematic diagram of auxiliary gadget operation MThings User Manual (Complete Version)Figure1701. Click on the "Auxiliary" main menu to enter the auxiliary page.

Put this resource to use in a real project?

Go to the Tool Center for message parsing, CRC verification and device debugging, or submit your requirements for selection and integration advice.

Engineer Membership

Turn this article into actionable debugging resources

After activation, you can use advanced message parsing, resource pack downloads, code examples, engineering cases and priority technical support, suitable for real project delivery.

Unlimited Advanced Tools
Resource & Code Packs
Complete Engineering Case Library
Priority Technical Support